NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.
myVolts
Adjustable 0-60V, 0-5A DC power supply with dual display, CV/CC auto-switching and short-circuit, over-temperature and current-limit protection
The myVolts STP6005D is a bench-top DC power supply with a continuously adjustable output of 0-60V and 0-5A. It operates in automatic constant voltage and constant current crossover mode. Independent dual displays show voltage and current simultaneously. Efficiency reaches 80 percent. Built-in protections include current-limiting buck, short-circuit and over-temperature safeguards.
This supply replaces fixed-voltage adapters or single-range bench units when a wider 0-60V span and 0-5A current capability are required. The jump is worth it for calibration stations, factory maintenance benches and test cabinet integration where both voltage and current must be set precisely. Regulation rates of 0.5% plus 3mV for voltage and 0.2% plus 3mA for current support repeatable results.
Verify that the AC input environment matches the 250VAC F5AL fuse specification. Confirm the ambient temperature stays within 0 to 40 degrees Celsius and relative humidity below 80 percent. Ensure the load does not exceed the 5A maximum and that the 50mVrms voltage ripple and 50mArms current ripple are acceptable for the intended test circuit.
| Type | AT |
|---|
The unit runs on a standard bench at 0 to 40 °C ambient and uses an F5AL 250 VAC fuse for mains protection.
Adjust the current knob first, then raise voltage; the supply auto-switches to CC at the preset limit and holds 0.5 % + 3 mV line regulation.
Inspect the F5AL 250 VAC fuse after any overload event and verify airflow if the unit runs continuously above 3 A where load regulation shifts to 0.2 % + 5 mV.
Også i denne avdelingen
Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.
Det du betaler med, og det du ser prisene i.
Sendes fra lommeboken din i kassen
Kun visning — katalogen er prissatt i USD
Fant ingen valuta.
Velg språket nettstedet snakker til deg på.
Ny her?
Har du allerede en konto?
Det finnes ingen automatisk tilbakestilling: butikken sender ikke e-post, så det finnes ingen engangslenke å be om. La adressen stå på kontoen, så blir den behandlet manuelt.
Forespørsel registrert
Ingenting er på vei til innboksen din — butikken sender ingen e-post i det hele tatt. Noen behandler dette manuelt.
Husket du det likevel?