Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
myVolts
Adjustable 0-60V, 0-5A DC power supply with dual display, CV/CC auto-switching and short-circuit, over-temperature and current-limit protection
The myVolts STP6005D is a bench-top DC power supply with a continuously adjustable output of 0-60V and 0-5A. It operates in automatic constant voltage and constant current crossover mode. Independent dual displays show voltage and current simultaneously. Efficiency reaches 80 percent. Built-in protections include current-limiting buck, short-circuit and over-temperature safeguards.
This supply replaces fixed-voltage adapters or single-range bench units when a wider 0-60V span and 0-5A current capability are required. The jump is worth it for calibration stations, factory maintenance benches and test cabinet integration where both voltage and current must be set precisely. Regulation rates of 0.5% plus 3mV for voltage and 0.2% plus 3mA for current support repeatable results.
Verify that the AC input environment matches the 250VAC F5AL fuse specification. Confirm the ambient temperature stays within 0 to 40 degrees Celsius and relative humidity below 80 percent. Ensure the load does not exceed the 5A maximum and that the 50mVrms voltage ripple and 50mArms current ripple are acceptable for the intended test circuit.
| Type | AT |
|---|
The unit runs on a standard bench at 0 to 40 °C ambient and uses an F5AL 250 VAC fuse for mains protection.
Adjust the current knob first, then raise voltage; the supply auto-switches to CC at the preset limit and holds 0.5 % + 3 mV line regulation.
Inspect the F5AL 250 VAC fuse after any overload event and verify airflow if the unit runs continuously above 3 A where load regulation shifts to 0.2 % + 5 mV.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?