Acceptăm criptomonede — astfel, criptomonedele pe care le dețineți pot cumpăra echipamente reale.Plătiți în cripto, cheltuiți-o pe echipamente reale. Livrare asigurată gratuită oriunde în lume peste 399 $. Cartoane neutre, fără marcă, expediate din Germania.Livrare asigurată gratuită peste 399 $. Cursul dumneavoastră este blocat timp de 30 de minute de la deschiderea paginii de plată.Curs blocat 30 de minute. Fiecare articol este sigilat, numărul de serie este verificat, iar produsul este acoperit de o garanție de 24 de luni.Sigilat, garantat 24 de luni.

Produse urmărite Conectare

Tripp Lite

Tripp Lite 9PX6KP1G2 6000VA 5400W 208/120V UPS

SKU CH-Y36G-D4YXG MPN 9PX6KP1G2

Online double-conversion UPS delivering 6000 VA and 5400 W with 120 V, 208 V and 240 V outputs, six 5-20R, one L6-30R and one L14-30R outlet, plus a Gigabit network card for remote management

  • Input Voltage Range230 V AC
  • VA Rating6000 VA
  • Watts5400 W
  • Output Voltage240 V AC 230 V AC 220 V AC 208 V AC 200 V AC 100 V AC 110 V
  • Output Frequency50 Hz 60 Hz
  • Outlets6 x NEMA 5-20R 1 x NEMA L6-30R 1 x NEMA L14-30R
  • Online double-conversion topology delivers clean sine-wave power
  • 6 kVA / 5.4 kW capacity supports dense IT loads
  • Six 5-20R, one L6-30R and one L14-30R outlets connect varied gear
  • Cybersecure Gigabit network card enables remote monitoring
  • 3-hour recharge restores full runtime after an outage

6 kVA Online UPS for Critical IT Loads

The Eaton 9PX G2 9PX6KP1G2 delivers 6000 VA and 5400 W of pure-sine-wave power through an online double-conversion topology. It accepts a wide 100–240 V AC input range and supplies selectable 120 V, 208 V, 200 V, 220 V, 230 V or 240 V output at 50 or 60 Hz. Eight outlets — six NEMA 5-20R, one L6-30R and one L14-30R — connect servers, storage and network gear in a 6U rack or tower form factor. A factory-installed NETWORK-M3 Gigabit card enables secure remote management.

Sustained Runtime and Thermal Behaviour

At full 5400 W load the internal valve-regulated lead-acid battery provides 3 minutes of backup; at half load the runtime extends to 8.30 minutes. Typical recharge completes in 3 hours. The unit operates continuously from 0 to 40 °C in 0–95 % non-condensing humidity. Online conversion isolates connected equipment from every input disturbance without switching delay, so voltage sags, surges and frequency drift never reach the load.

Replaces Standby or Line-Interactive Units

This UPS steps up from standby or line-interactive models that only condition power during anomalies. The jump is worth it when equipment cannot tolerate any transfer time, when harmonic distortion must stay below 3 %, or when remote shutdown and firmware updates over a hardened network card are required. It is not suited for installations that need longer battery autonomy without adding external packs, nor for sites limited to 120 V input-only wiring.

Puncte forte

  • Online double-conversion topology delivers clean sine-wave power
  • 6 kVA / 5.4 kW capacity supports dense IT loads
  • Six 5-20R, one L6-30R and one L14-30R outlets connect varied gear
  • Cybersecure Gigabit network card enables remote monitoring
  • 3-hour recharge restores full runtime after an outage

Specificații

BrandEATON
Model9PX6KP1G2
Part Number9PX6KP1G2
Input Voltage Range230 V AC
VA Rating6000 VA
Watts5400 W
Output Voltage240 V AC
230 V AC
220 V AC
208 V AC
200 V AC
100 V AC
110 V AC
120 V AC
Output Frequency50 Hz
60 Hz
Outlets6 x NEMA 5-20R
1 x NEMA L6-30R
1 x NEMA L14-30R
Battery TypeDC System Voltage:
180 V DC
Battery Characteristics:
Valve-regulated
Battery Chemistry:
Lead Acid
Battery Run TimeBackup/Run Time (Full Load):
3 Minute
Backup/Run Time (Half Load):
8.30 Minute
Battery Recharge TimeTypical Battery Recharge Time:
3 Hour
DimensionsHeight:
10.20"
Width:
17.30"
Depth:
27"
Weight203 lb
Package Contents9PX G2 9PX6KP1G2 6000VA Rack/tower UPS
9PXPPDM1G2 PowerPass Distribution Module with Maintenance Bypass
NETWORK-M3 Gigabit Network Card
USB Cable
RS-232 Cable
Rack-mounting Hardware
Tower Support Stands
Quick Start Guide
Greutate la expediere122.47 kg
Dimensiunile coletului991 × 711 × 635 mm

Întrebări despre acest articol

How much heat does the 5400 W online UPS add to a server room running 24/7?

At full load the unit delivers 5400 W of pure sine-wave power while maintaining best-in-class efficiency, so waste heat is kept to a minimum even during continuous operation.

What input plug and circuit must already exist on site for the L6-30P connection?

A single-phase 208 V or 240 V 30 A branch circuit with an L6-30R receptacle is required to feed the UPS input.

Will the L14-30R and L6-30R outlets power legacy 208 V gear alongside the six 5-20R sockets?

Yes, the UPS simultaneously provides 120 V on the 5-20R outlets and 208 V or 240 V on the L6-30R and L14-30R outlets, so older 208 V equipment can stay connected.