Tripp Lite 9PX6KP1G2 6000VA 5400W 208/120V UPS
Online double-conversion UPS delivering 6000 VA and 5400 W with 120 V, 208 V and 240 V outputs, six 5-20R, one L6-30R and one L14-30R outlet, plus a Gigabit network card for remote management
- Input Voltage Range230 V AC
- VA Rating6000 VA
- Watts5400 W
- Output Voltage240 V AC 230 V AC 220 V AC 208 V AC 200 V AC 100 V AC 110 V
- Output Frequency50 Hz 60 Hz
- Outlets6 x NEMA 5-20R 1 x NEMA L6-30R 1 x NEMA L14-30R
- Online double-conversion topology delivers clean sine-wave power
- 6 kVA / 5.4 kW capacity supports dense IT loads
- Six 5-20R, one L6-30R and one L14-30R outlets connect varied gear
- Cybersecure Gigabit network card enables remote monitoring
- 3-hour recharge restores full runtime after an outage
6 kVA Online UPS for Critical IT Loads
The Eaton 9PX G2 9PX6KP1G2 delivers 6000 VA and 5400 W of pure-sine-wave power through an online double-conversion topology. It accepts a wide 100–240 V AC input range and supplies selectable 120 V, 208 V, 200 V, 220 V, 230 V or 240 V output at 50 or 60 Hz. Eight outlets — six NEMA 5-20R, one L6-30R and one L14-30R — connect servers, storage and network gear in a 6U rack or tower form factor. A factory-installed NETWORK-M3 Gigabit card enables secure remote management.
Sustained Runtime and Thermal Behaviour
At full 5400 W load the internal valve-regulated lead-acid battery provides 3 minutes of backup; at half load the runtime extends to 8.30 minutes. Typical recharge completes in 3 hours. The unit operates continuously from 0 to 40 °C in 0–95 % non-condensing humidity. Online conversion isolates connected equipment from every input disturbance without switching delay, so voltage sags, surges and frequency drift never reach the load.
Replaces Standby or Line-Interactive Units
This UPS steps up from standby or line-interactive models that only condition power during anomalies. The jump is worth it when equipment cannot tolerate any transfer time, when harmonic distortion must stay below 3 %, or when remote shutdown and firmware updates over a hardened network card are required. It is not suited for installations that need longer battery autonomy without adding external packs, nor for sites limited to 120 V input-only wiring.
特長
- Online double-conversion topology delivers clean sine-wave power
- 6 kVA / 5.4 kW capacity supports dense IT loads
- Six 5-20R, one L6-30R and one L14-30R outlets connect varied gear
- Cybersecure Gigabit network card enables remote monitoring
- 3-hour recharge restores full runtime after an outage
仕様
| Brand | EATON |
|---|---|
| Model | 9PX6KP1G2 |
| Part Number | 9PX6KP1G2 |
| Input Voltage Range | 230 V AC |
| VA Rating | 6000 VA |
| Watts | 5400 W |
| Output Voltage | 240 V AC 230 V AC 220 V AC 208 V AC 200 V AC 100 V AC 110 V AC 120 V AC |
| Output Frequency | 50 Hz 60 Hz |
| Outlets | 6 x NEMA 5-20R 1 x NEMA L6-30R 1 x NEMA L14-30R |
| Battery Type | DC System Voltage: 180 V DC Battery Characteristics: Valve-regulated Battery Chemistry: Lead Acid |
| Battery Run Time | Backup/Run Time (Full Load): 3 Minute Backup/Run Time (Half Load): 8.30 Minute |
| Battery Recharge Time | Typical Battery Recharge Time: 3 Hour |
| Dimensions | Height: 10.20" Width: 17.30" Depth: 27" |
| Weight | 203 lb |
| Package Contents | 9PX G2 9PX6KP1G2 6000VA Rack/tower UPS 9PXPPDM1G2 PowerPass Distribution Module with Maintenance Bypass NETWORK-M3 Gigabit Network Card USB Cable RS-232 Cable Rack-mounting Hardware Tower Support Stands Quick Start Guide |
| 配送重量 | 122.47 kg |
| 梱包サイズ | 991 × 711 × 635 mm |
この商品に関する質問
How much heat does the 5400 W online UPS add to a server room running 24/7?
At full load the unit delivers 5400 W of pure sine-wave power while maintaining best-in-class efficiency, so waste heat is kept to a minimum even during continuous operation.
What input plug and circuit must already exist on site for the L6-30P connection?
A single-phase 208 V or 240 V 30 A branch circuit with an L6-30R receptacle is required to feed the UPS input.
Will the L14-30R and L6-30R outlets power legacy 208 V gear alongside the six 5-20R sockets?
Yes, the UPS simultaneously provides 120 V on the 5-20R outlets and 208 V or 240 V on the L6-30R and L14-30R outlets, so older 208 V equipment can stay connected.