NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Prijímame kryptomeny — takže mince, ktoré držíte, môžete zameniť za skutočný hardvér.Plaťte v krypte, miňte ho na skutočný hardvér. Poistená doprava zadarmo po celom svete nad 399 $. Neutrálne kartóny bez potlače, odosielané z Nemecka.Poistená doprava zadarmo nad 399 $. Váš kurz je zablokovaný na 30 minút hneď po otvorení pokladne.Kurz zablokovaný na 30 minút. Každý produkt je zapečatený, jeho sériové číslo je overené a vzťahuje sa naň 24-mesačná záruka.Zapečatené, 24-mesačná záruka.
Goldshell
Kadena ASIC miner delivering 40.2 Th/s at 3350 W with four fans rated at 80 dB
The Goldshell KD MAX is a dedicated crypto mining machine built for Kadena algorithm work. It delivers a rated hashrate of 40.2 TH/s with a tolerance of ±5 percent. The unit ships in new condition and was released in June 2022. It connects to the network through a wired Ethernet interface.
Four integrated fans move air through the chassis to manage heat during continuous operation. The manufacturer specifies a noise level of 80 dB under load. Power draw is rated at 3350 W and the power supply accepts an input voltage range of 185 to 285 V. The operating temperature window spans 0 to 35 °C with a relative humidity tolerance of 5 to 95 percent.
The enclosure measures 200 x 264 x 290 mm and weighs 8.1 kg, allowing it to fit on standard shelving or rack trays. No additional accessories or proprietary software packages are listed in the supplier data. The Ethernet port provides the sole management and pool connection path.
Pre tento produkt zatiaľ nie sú zverejnené žiadne špecifikácie.
Place the unit on a stable surface with clearance around its 200 x 264 x 290mm frame, connect an Ethernet cable for network access, then supply 185-285V power to reach 3350W. The step often missed is verifying the PDU and circuit can sustain the full 3350W draw continuously before powering on.
The four fans are the primary wear items; at 80dB noise they move significant air and bearings degrade over time. Plan to clean dust from the intake and exhaust paths every few months and replace any fan that develops vibration or reduced airflow to keep temperatures within the -35°C to 95% humidity operating envelope.
The 3350W power ceiling and the 80dB cooling capacity set the practical ceiling. If inlet air approaches the upper ambient range or the four fans cannot exhaust heat fast enough, the unit will throttle hashrate below 40.2 TH/s to stay within thermal limits, making cooling headroom the first bottleneck.
Aj v tomto oddelení
Rovnaké oddelenie, rovnaká pokladňa — osem mien a kurz zablokovaný na 30 minút.
Mena, v ktorej platíte, a mena, v ktorej sa zobrazujú ceny.
Odoslané z vašej peňaženky na pokladni
Len na zobrazenie — katalóg je uvedený v dolároch
Žiadna mena nezodpovedá.
Vyberte jazyk, v ktorom s vami bude web komunikovať.
Ste tu prvýkrát?
Účet už máte?
Automatický reset hesla neexistuje: tento obchod neposiela žiadne e-maily, takže neexistuje jednorazový odkaz, o ktorý by ste mohli požiadať. Nechajte adresu na účte — niekto sa jej ujme ručne.
Žiadosť zaznamenaná
Do vašej schránky nič nepríde — tento obchod neposiela vôbec žiadne e-maily. Niekto sa o to postará ručne.
Spomenuli ste si?