HP
HP 511777-001 460W Common Slot Platinum Plus server power supply
A 460 W Common Slot Platinum Plus hot-plug power module delivers 12 V at 38.3 A with 92 % efficiency across 100–240 V input
- TypePower Module
- Input Voltage110 V AC 220 V AC
- Platinum Plus efficiency reaches 92% at typical load
- 460 W output with 38.3 A on the +12 V rail
- Hot-plug Common Slot design fits standard server bays
- Universal 100-240 V AC input covers global power grids
- Compact 7.5" x 3.4" x 1.5" form factor saves rack space
460W Common Slot power module
This 460W Common Slot power module delivers 12V at up to 38.3A and a 12V standby rail at 2.5A. It accepts 100-240V AC input at 50-60Hz and achieves 92% efficiency. The unit uses the black-plug Common Slot form factor and does not support power discovery services.
Suited for compatible HPE servers
It suits operators adding or replacing a hot-plug supply in a Common Slot bay that does not require power discovery. Builders needing power discovery support or a different wattage should look at other modules.
Black-plug Common Slot compatibility
The black-plug Common Slot interface is the single specification that decides fitment; the module will only work in bays designed for this exact connector and signalling type.
Prednosti
- Platinum Plus efficiency reaches 92% at typical load
- 460 W output with 38.3 A on the +12 V rail
- Hot-plug Common Slot design fits standard server bays
- Universal 100-240 V AC input covers global power grids
- Compact 7.5" x 3.4" x 1.5" form factor saves rack space
Špecifikácie
| Brand | HP |
|---|---|
| Type | Power Module |
| Input Voltage | 110 V AC 220 V AC |
| Prepravná hmotnosť | 2.27 kg |
| Rozmery balenia | 254 × 229 × 102 mm |
Otázky k tomuto produktu
Will the 7.5" depth, 3.4" width and 1.5" height fit my Common Slot bay?
The module measures approximately 7.5 inches deep, 3.4 inches wide and 1.5 inches high, matching the standard Common Slot form factor used in supported HPE servers.
What is the correct hot-plug insertion sequence to avoid a seating error?
Slide the unit straight into the bay until the latch clicks, then verify the green LED illuminates; forcing it at an angle can bend the connector pins.
How often should the internal fan be cleaned to maintain the 92% efficiency rating?
Inspect and blow out dust from the fan intake every six months, or more frequently in high-particulate environments, to preserve airflow and efficiency.
Aj v tomto oddelení
Zákazníci tiež porovnávali
Rovnaké oddelenie, rovnaká pokladňa — osem mien a kurz zablokovaný na 30 minút.