Prijímame kryptomeny — takže mince, ktoré držíte, môžete zameniť za skutočný hardvér.Plaťte v krypte, miňte ho na skutočný hardvér. Poistená doprava zadarmo po celom svete nad 399 $. Neutrálne kartóny bez potlače, odosielané z Nemecka.Poistená doprava zadarmo nad 399 $. Váš kurz je zablokovaný na 30 minút hneď po otvorení pokladne.Kurz zablokovaný na 30 minút. Každý produkt je zapečatený, jeho sériové číslo je overené a vzťahuje sa naň 24-mesačná záruka.Zapečatené, 24-mesačná záruka.

Sledované položky Prihlásiť sa

MINUTEMAN

MINUTEMAN RPM1516N1LCD-IEC PDU Switched 16-Outlet 15A IEC 0U Vertical

SKU CH-YG14-547GT MPN RPM1516N1LCD-IEC

A 15 A switched PDU with 16 NEMA 5-15R outlets, IP-addressable remote management, a local LCD for amps and temperature, and 0U vertical rack mounting

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current15A
  • Input Connector(s)IEC
  • Cord Length10 ft
  • Remote power control of up to 24 devices from a single IP address
  • Local LCD shows real-time amps, IP address, temperature and humidity
  • Built-in web server enables browser-based remote power management
  • Input circuit breaker protects connected equipment from overload events
  • 62368-1 certification confirms compliance with recognised safety standards

16-Outlet Switched PDU for Rack Deployment

The Minuteman RPM1516N1LCD-IEC is a 0U vertical power distribution unit built for server racks. It provides sixteen NEMA 5-15R receptacles fed from a single IEC inlet rated at 15 A. A 10 ft cord connects the unit to the upstream supply. An integrated circuit breaker protects the entire strip from overloads.

Suited for Remote Reboot and Monitoring Needs

Network operators who need to power-cycle individual devices from a browser or SNMP console will benefit from the IP-addressable manager and per-outlet switching. The local LCD shows current draw, IP address, temperature and humidity at a glance. Facilities that require only basic power distribution without network control or environmental readouts should consider a simpler strip.

15 A Input and Output Current Limit

The unit accepts a maximum of 15 A at the IEC inlet and delivers no more than 15 A in total across all sixteen outlets. Verify that the combined load of connected equipment stays within this 15 A ceiling before installation.

Prednosti

  • Remote power control of up to 24 devices from a single IP address
  • Local LCD shows real-time amps, IP address, temperature and humidity
  • Built-in web server enables browser-based remote power management
  • Input circuit breaker protects connected equipment from overload events
  • 62368-1 certification confirms compliance with recognised safety standards

Špecifikácie

BrandMINUTEMAN
ModelRPM1516N1LCD-IEC
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current15A
Input Connector(s)IEC
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (16) 5-15 R
Maximum Output Current15A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Prepravná hmotnosť4.99 kg
Rozmery balenia1359 × 221 × 109 mm

Ďalšie verzie tohto modelu

Ďalších 5 v tomto rade

Rovnaký rad, iná pamäť, chladič alebo frekvencia — porovnajte pred rozhodnutím.

Otázky k tomuto produktu

What network interface does the RPM1516N1LCD-IEC use, and what speed does it cap at?

It connects through a 10/100 Base-T Ethernet port, so the network link tops out at 100 Mbps.

What rack space and orientation does the 0U vertical design require?

The unit mounts vertically in a rack without consuming any horizontal U-space, using its 0U form factor.

How is the PDU initially configured, and which step is often missed?

Connect the RJ-45 cable, assign a static IP or enable DHCP through the web browser or SSH, then create user accounts with the three permission levels before setting outlet schedules.

Aj v tomto oddelení

Zákazníci tiež porovnávali

Rovnaké oddelenie, rovnaká pokladňa — osem mien a kurz zablokovaný na 30 minút.