MINUTEMAN EC1500RTXL2U 1500VA 1350W 120V 2U Rack/Tower Online UPS
- 120V
- 0-160VAC
Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
MINUTEMAN
Provides true on-line double-conversion backup with LCD monitoring, six controllable NEMA 5-15R outlets, and hot-swappable battery for critical equipment
Model EC1000LCD
Prečrtane različice obstajajo, vendar tukaj niso na voljo.
The Minuteman EC1000LCD is a 1000VA 900W tower UPS that uses true on-line double-conversion technology to regenerate the incoming AC signal. It delivers pure sinewave output at 110V 120V or 127V with a 0.9 output power factor. Six NEMA 5-15R receptacles provide controllable outlet banks for connected equipment. The unit suits critical loads in data centres voice and data communications security systems and light industrial applications.
Operating temperature range spans 32 to 104°F (0 to 40°C) while storage reaches 14 to 122°F (-10 to 50°C). Input voltage range covers 0 to 160VAC with auto-sensing 50/60Hz frequency. The 140 joule surge energy rating handles spikes. Economy mode option improves efficiency during normal operation. Battery run time provides 10 minutes at half load and 2 minutes at full load with an 8 hour recharge to 90 percent.
Tower form factor measures 10.2 inches high 6.1 inches wide and 15.9 inches deep. Input connects via NEMA 5-15P plug. A DB-9 serial port enables management through SentryHD software while an optional SNMP card adds network monitoring. Hot-swappable battery replacement uses BM0076 modules. Independent battery bypass maintains voltage regulation and surge protection even with dead or removed batteries. Extended runtime capability supports additional battery packs for longer backup.
| Brand | MINUTEMAN |
|---|---|
| Model | EC1000LCD |
| International Version | 120V |
| Input Voltage Range | 0-160VAC |
| Input Frequency | 50/60Hz +/- 6Hz Auto-sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000VA |
| Watts | 900W |
| Output Voltage | 120V |
| Output Frequency | 50/60Hz +/-0.2Hz unless synchronized to line |
| Outlets | 6 |
| Outlet Type | (6) NEMA 5-15R (controllable) |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Half Load: 10 min Full Load: 2 min |
| Battery Recharge Time | 8 hours to 90% from total discharge |
| Battery Replaceable | BM0076 |
| Interface Port | DB-9 |
| Approvals | cULus (UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class A, CE certified, RoHS2 (EU Directive 2011/65/EU & 2015/863/EU) |
| Surge Energy Rating | 140 Joules |
| Temperature | Operating Temperature +32 to +104°F (0 to 40°C) Storage Temperature +14 to +122°F (-10 to +50°C) |
| Humidity | 10% to 90% non-condensing |
| Dimensions | 10.2" x 15.9" x 6.1" |
| Weight | 28.2 lbs. |
| Teža pošiljke | 14.06 kg |
| Velikost pošiljke | 495 × 375 × 260 mm |
Druge različice tega modela
Ista družina, različen pomnilnik, hladilnik ali takt — primerjajte, preden se odločite.
Connect the NEMA 5-15P input plug to a 120 V AC branch circuit, attach loads to the six NEMA 5-15R outlets, then configure the two controllable outlet banks via the LCD or SentryHD software; the step often missed is assigning each load to the correct bank so non-critical devices shed first during extended outages.
The sealed lead-acid battery (part BM0076) is hot-swappable and typically requires replacement every three to five years; recharge takes 8 hours to 90 % after a full discharge, and the independent battery bypass lets the UPS continue surge protection even with the battery removed.
At 900 W the internal battery provides only 2 minutes of runtime, so battery endurance is the first constraint; the unit also operates between 0 and 40 °C, and sustained full-load operation will approach the thermal limit before the 140-joule surge rating or the 0.9 power factor become factors.
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Ni ustreznega jezika.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?