MINUTEMAN EC1500RTXL2U 1500VA 1350W 120V 2U Rack/Tower Online UPS
- 120V
- 0-160VAC
MINUTEMAN
Provides true on-line double-conversion backup with LCD monitoring, six controllable NEMA 5-15R outlets, and hot-swappable battery for critical equipment
Model EC1000LCD
取り消し線の付いたバージョンは存在しますが、こちらでは取り扱っていません。
The Minuteman EC1000LCD is a 1000VA 900W tower UPS that uses true on-line double-conversion technology to regenerate the incoming AC signal. It delivers pure sinewave output at 110V 120V or 127V with a 0.9 output power factor. Six NEMA 5-15R receptacles provide controllable outlet banks for connected equipment. The unit suits critical loads in data centres voice and data communications security systems and light industrial applications.
Operating temperature range spans 32 to 104°F (0 to 40°C) while storage reaches 14 to 122°F (-10 to 50°C). Input voltage range covers 0 to 160VAC with auto-sensing 50/60Hz frequency. The 140 joule surge energy rating handles spikes. Economy mode option improves efficiency during normal operation. Battery run time provides 10 minutes at half load and 2 minutes at full load with an 8 hour recharge to 90 percent.
Tower form factor measures 10.2 inches high 6.1 inches wide and 15.9 inches deep. Input connects via NEMA 5-15P plug. A DB-9 serial port enables management through SentryHD software while an optional SNMP card adds network monitoring. Hot-swappable battery replacement uses BM0076 modules. Independent battery bypass maintains voltage regulation and surge protection even with dead or removed batteries. Extended runtime capability supports additional battery packs for longer backup.
| Brand | MINUTEMAN |
|---|---|
| Model | EC1000LCD |
| International Version | 120V |
| Input Voltage Range | 0-160VAC |
| Input Frequency | 50/60Hz +/- 6Hz Auto-sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000VA |
| Watts | 900W |
| Output Voltage | 120V |
| Output Frequency | 50/60Hz +/-0.2Hz unless synchronized to line |
| Outlets | 6 |
| Outlet Type | (6) NEMA 5-15R (controllable) |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Half Load: 10 min Full Load: 2 min |
| Battery Recharge Time | 8 hours to 90% from total discharge |
| Battery Replaceable | BM0076 |
| Interface Port | DB-9 |
| Approvals | cULus (UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class A, CE certified, RoHS2 (EU Directive 2011/65/EU & 2015/863/EU) |
| Surge Energy Rating | 140 Joules |
| Temperature | Operating Temperature +32 to +104°F (0 to 40°C) Storage Temperature +14 to +122°F (-10 to +50°C) |
| Humidity | 10% to 90% non-condensing |
| Dimensions | 10.2" x 15.9" x 6.1" |
| Weight | 28.2 lbs. |
| 配送重量 | 14.06 kg |
| 梱包サイズ | 495 × 375 × 260 mm |
このモデルの他のバージョン
同じファミリーで、メモリ・クーラー・クロックが異なります — 購入前に比較してください。
Connect the NEMA 5-15P input plug to a 120 V AC branch circuit, attach loads to the six NEMA 5-15R outlets, then configure the two controllable outlet banks via the LCD or SentryHD software; the step often missed is assigning each load to the correct bank so non-critical devices shed first during extended outages.
The sealed lead-acid battery (part BM0076) is hot-swappable and typically requires replacement every three to five years; recharge takes 8 hours to 90 % after a full discharge, and the independent battery bypass lets the UPS continue surge protection even with the battery removed.
At 900 W the internal battery provides only 2 minutes of runtime, so battery endurance is the first constraint; the unit also operates between 0 and 40 °C, and sustained full-load operation will approach the thermal limit before the 140-joule surge rating or the 0.9 power factor become factors.
同じ売り場の商品
同じ売り場、同じレジ — 8種類のコインと30分間のレートロック。
お支払いに使うコインと、価格表示に使う通貨です。
チェックアウト時にウォレットから送信されます。
表示のみ—カタログの価格は米ドル建てです。
該当する通貨がありません。
サイトの表示言語を選択してください。
一致する言語がありません。
初めてのご利用ですか?
すでにお持ちですか?
自動的な再設定はありません。当店はメールを送信しないため、ワンタイムリンクをお送りすることもできません。アカウントにメールアドレスを残しておいていただければ、担当者が手作業で確認いたします。
リクエストを受け付けました
受信箱に何かが届くことはありません — 当店はメールを一切送信していません。担当者が手作業で確認いたします。
思い出しましたか?