Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.

Spremljani izdelki Prijava

MINUTEMAN

MINUTEMAN OEPD2415V62 PDU 24-Outlet 15A 120V 15ft Cord 0U Vertical

SKU CH-SKGH-XWKWC MPN OEPD2415V62

Distributes 120 V power to 24 NEMA 5-15R outlets from a single 15 A NEMA 5-15P input with a 15 ft cord for flexible 0U vertical mounting

  • Rack Size1U
  • Style0U Vertical Installation
  • CertificationsUL 60950-1, cUL, CE
  • Maximum Input Current15A
  • Input Connector(s)NEMA 5-15P
  • Cord Length15 ft

Prečrtane različice obstajajo, vendar tukaj niso na voljo.

  • 24 NEMA 5-15R outlets power dense equipment racks
  • 15 ft cord length enables flexible vertical placement
  • 0U form factor preserves rack space for servers
  • UL 60950-1 and cUL certifications confirm safety compliance
  • Switchless design with LED indicators increases operational reliability

24-Outlet PDU for Dense Racks

The Minuteman OEPD2415V62 is a vertical power distribution unit built for datacentres, telecom rooms and security installations. It delivers 120 V AC through twenty-four NEMA 5-15R receptacles fed by a single NEMA 5-15P input plug rated at 15 A. The 0U form factor mounts vertically or horizontally without consuming rack units, and the switchless design with on/off LEDs maximises mean time between failure.

Thermals Noise and Power Draw

Passive operation means no fans and no audible noise in normal use. The unit simply distributes up to 12 A of continuous output current through heavy-gauge, strain-relieved conductors. A moulded input plug and external ground stud provide secure connections, while the 15 ft cord length gives routing flexibility without adding active cooling requirements.

Build Integration and Mounting

Vertical 0U mounting frees the full 1U rack height for servers, switches or patch panels. The long input cord reaches distant power sources, reducing the need for extension leads. UL 60950-1, cUL and CE certifications confirm compliance for professional environments. Buyers who need switched outlets, metering or higher amperage circuits will require a different PDU class.

Poudarki

  • 24 NEMA 5-15R outlets power dense equipment racks
  • 15 ft cord length enables flexible vertical placement
  • 0U form factor preserves rack space for servers
  • UL 60950-1 and cUL certifications confirm safety compliance
  • Switchless design with LED indicators increases operational reliability

Specifikacije

BrandMINUTEMAN
SeriesOE Series
ModelOEPD2415V62
Rack Size1U
Style0U Vertical Installation
CertificationsUL 60950-1, cUL, CE
Maximum Input Current15A
Input Connector(s)NEMA 5-15P
Cord Length15 ft
Output Connector(s)(24) 5-15R
FeaturesLonger power cords
Most Minuteman PDU units have up to 15-ft power cords, to allow for seamless installations
More standard outlets
Minuteman PDU units have 6, 8, 10, 14, 18, or 24 outlets. Most of the Minuteman PDUs have additional front outlets for improved access
Configuration versatility
Minuteman PDU units have a multi-form factor with 1U and 0U configurations allowing for either horizontal or vertical placement. 1U products ship with a stand-off mounting bracket, at no additional cost, that allows for vertical installation on most racks and enclosures
Locking (L) and Hardwire (
Teža pošiljke2.99 kg
Velikost pošiljke1656 × 127 × 76 mm

Druge različice tega modela

še 5 v isti paleti

Ista družina, različen pomnilnik, hladilnik ali takt — primerjajte, preden se odločite.

Vprašanja o tem izdelku

How do I install the OEPD2415V62 vertically in a 0U rack, and what step is often missed?

Mount the unit using its 0U vertical brackets on the rack side rails, then connect the 15 ft NEMA 5-15P cord to a 15 A branch circuit; the step often missed is securing the external ground stud to the rack for proper bonding.

What maintenance or replacement will the OEPD2415V62 need over time?

The switchless design has no user-serviceable parts; inspect the 24 NEMA 5-15R outlets and the strain-relieved 15 ft cord periodically for wear, and replace the entire PDU if any receptacle shows damage or the cord insulation degrades.

What limit appears first when the OEPD2415V62 runs continuously at full load?

The 15 A input rating (120 V, 12 A max output) is the first limit; drawing more than 15 A will trip the upstream branch breaker, so total connected equipment must stay at or below 12 A continuous.