Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.

Spremljani izdelki Prijava

MINUTEMAN

MINUTEMAN OEPD304L630HVHW PDU 208VAC 30A (2) L6-20R (2) L6-30R Hardwire 6ft 1U/0U

SKU CH-F9TS-PZNHD MPN OEPD304L630HVHW

Distributes 208 VAC power at 30 A through two L6-20R and two L6-30R outlets with hardwire input and 1U or 0U mounting

  • Rack Size1U
  • StyleHorizontal Installation , 0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current30A
  • Input Connector(s)Hardwire
  • Cord Length6 ft

Prečrtane različice obstajajo, vendar tukaj niso na voljo.

  • Delivers 208 VAC three-phase power for dense rack loads
  • 30 A input rating supports high-density equipment deployments
  • Four locking outlets: two L6-20R and two L6-30R for mixed device plugs
  • Hardwire input with 6 ft cord enables permanent, code-compliant installation
  • 1U/0U convertible mounting fits horizontal or vertical rack orientations

PDU 208VAC 30A Hardwire Input

The Minuteman OEPD304L630HVHW is a power distribution unit that delivers 208VAC at up to 30 amps through a hardwire input connection. It mounts horizontally in 1U of rack space or vertically in a 0U configuration using the included stand-off bracket. Two L6-20R and two L6-30R outlets provide four locking receptacles for connected equipment. A six-foot input cord and UL 62368-1 certification complete the unit.

Suits Racks Needing Four Locking Outlets

This PDU fits server rooms and network cabinets that require a hardwire feed and a mix of 20-amp and 30-amp locking outlets in a compact form factor. It is not for installations that need a plug-in input cord, more than four output receptacles, or voltage other than 208VAC.

30-Amp Hardwire Feed Decides Fit

The single specification that determines suitability is the 30-amp hardwire input; the building circuit and wiring must support that rating and connection method. If the supply is limited to a lower amperage or only standard plug connectors, this unit will not work.

Poudarki

  • Delivers 208 VAC three-phase power for dense rack loads
  • 30 A input rating supports high-density equipment deployments
  • Four locking outlets: two L6-20R and two L6-30R for mixed device plugs
  • Hardwire input with 6 ft cord enables permanent, code-compliant installation
  • 1U/0U convertible mounting fits horizontal or vertical rack orientations

Specifikacije

BrandMINUTEMAN
SeriesOE Series
ModelOEPD304L630HVHW
Rack Size1U
StyleHorizontal Installation , 0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current30A
Input Connector(s)Hardwire
Cord Length6 ft
Output Connector(s)(2) L6-20R / (2) L6-30R
Overload ProtectionInput Circuit Breaker Protection
FeaturesLonger power cords
Most Minuteman PDU units have up to 15-ft power cords, to allow for seamless installations
More standard outlets
Minuteman PDU units have 6, 8, 10, 14, 18, or 24 outlets. Most of the Minuteman PDUs have additional front outlets for improved access
Configuration versatility
Minuteman PDU units have a multi-form factor with 1U and 0U configurations allowing for either horizontal or vertical placement. 1U products ship with a stand-off mounting bracket, at no additional cost, that allows for vertical installation on most racks and enclosures
Locking (L) and Hardwire (
Teža pošiljke3.13 kg
Velikost pošiljke432 × 130 × 46 mm

Druge različice tega modela

še 5 v isti paleti

Ista družina, različen pomnilnik, hladilnik ali takt — primerjajte, preden se odločite.

Vprašanja o tem izdelku

What outlets and input connection does the OEPD304L630HVHW include, and does it ship with any mounting hardware?

The unit provides two L6-20R and two L6-30R outlets, a 6-foot hardwire input cord, and a stand-off bracket for 0U vertical mounting in standard racks.

How do I decide between the L6-20R and L6-30R outlets for my equipment?

Match each device to the outlet that fits its plug; L6-20R accepts 20-amp locking plugs while L6-30R accepts 30-amp locking plugs, both at 208 VAC.

What does the 30-amp rating mean for actual power delivery in a 208 VAC rack?

It allows up to 30 amps continuous draw across all four outlets combined, with the built-in input circuit breaker tripping if that limit is exceeded.