NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
myVolts
A regulated DC bench supply delivering 0–30 V and 0–10 A with over-voltage and over-current protection, four-digit LED readouts and a rugged metal case
This myVolts regulated DC power supply delivers adjustable output from 0 to 30 V and 0 to 10 A for prototyping, service benches and classroom work. The four‑digit LED display shows voltage and current simultaneously so you can set limits at a glance. Rugged metal housing makes it suited to daily use in manufacturing, university labs and appliance repair shops. It runs from a 220 V AC mains input at 50 Hz.
Forced‑air cooling keeps internal temperatures in check while the unit operates within the rated 0 to 40 °C ambient range. Fan noise remains low enough for bench‑side conversation during normal voltage and current levels. Power draw follows the load, so idle consumption is minimal and efficiency stays high across the working range. The metal chassis also acts as a heatsink, spreading warmth without hotspots.
The supply maintains stable regulation during extended runs thanks to built‑in over‑voltage and over‑current protection that clamps transients without shutdown. Accuracy is specified at 23 ± 5 °C, so prolonged operation near full output stays within tolerance if ambient conditions are met. Ventilation gaps of at least 10 cm are recommended to sustain airflow during long sessions. Storage extremes of -20 to 60 °C do not affect calibration once the unit returns to normal conditions.
| Type | AT |
|---|
Connect the AC cord to a 220V 50Hz outlet, ensure the L terminal goes to the live wire and the ground wire is properly grounded before switching on.
Keep ventilation gaps clear and operate within 0–40°C and 80% RH; the rugged metal chassis and OVP/OCP protection reduce wear, so no scheduled part changes are required.
The 10A current ceiling or the 40°C ambient temperature limit will be reached before the 30V voltage maximum under continuous load.
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?