NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Přijímáme kryptoměny — takže to, co držíte, můžete utratit za skutečný hardware.Plaťte kryptem, utrácejte ho za skutečný hardware. Pojištěná doprava zdarma po celém světě nad 399 $. Neutrální přepravní krabice bez loga, odesílané z Německa.Pojištěná doprava zdarma nad 399 $. Jakmile se otevře pokladna, je váš kurz zablokovaný na 30 minut.Kurz zablokovaný na 30 minut. Každý výrobek je zapečetěný, jeho sériové číslo je zkontrolované a vztahuje se na něj 24měsíční záruka.Zapečetěno, záruka 24 měsíců.
myVolts
A regulated DC bench supply delivering 0–30 V and 0–10 A with over-voltage and over-current protection, four-digit LED readouts and a rugged metal case
This myVolts regulated DC power supply delivers adjustable output from 0 to 30 V and 0 to 10 A for prototyping, service benches and classroom work. The four‑digit LED display shows voltage and current simultaneously so you can set limits at a glance. Rugged metal housing makes it suited to daily use in manufacturing, university labs and appliance repair shops. It runs from a 220 V AC mains input at 50 Hz.
Forced‑air cooling keeps internal temperatures in check while the unit operates within the rated 0 to 40 °C ambient range. Fan noise remains low enough for bench‑side conversation during normal voltage and current levels. Power draw follows the load, so idle consumption is minimal and efficiency stays high across the working range. The metal chassis also acts as a heatsink, spreading warmth without hotspots.
The supply maintains stable regulation during extended runs thanks to built‑in over‑voltage and over‑current protection that clamps transients without shutdown. Accuracy is specified at 23 ± 5 °C, so prolonged operation near full output stays within tolerance if ambient conditions are met. Ventilation gaps of at least 10 cm are recommended to sustain airflow during long sessions. Storage extremes of -20 to 60 °C do not affect calibration once the unit returns to normal conditions.
| Type | AT |
|---|
Connect the AC cord to a 220V 50Hz outlet, ensure the L terminal goes to the live wire and the ground wire is properly grounded before switching on.
Keep ventilation gaps clear and operate within 0–40°C and 80% RH; the rugged metal chassis and OVP/OCP protection reduce wear, so no scheduled part changes are required.
The 10A current ceiling or the 40°C ambient temperature limit will be reached before the 30V voltage maximum under continuous load.
Také v této kategorii
Stejná kategorie, stejná pokladna — osm měn a kurz zamčený na 30 minut.
Měna, ve které platíte, a měna, ve které se zobrazují ceny.
Odesláno z vaší peněženky u pokladny
Pouze pro zobrazení — katalog je veden v dolarech
Žádná měna neodpovídá.
Vyberte jazyk, ve kterém s vámi bude web komunikovat.
Poprvé tady?
Už účet máte?
Neexistuje žádná automatická obnova hesla: tento obchod neposílá žádné e-maily, takže neexistuje jednorázový odkaz, o který by bylo možné požádat. Nechte adresu uvedenou u účtu, vyřídíme ji ručně.
Žádost zaznamenána
Do vaší schránky nic nedorazí — tento obchod neposílá žádné e-maily. Někdo se o to postará ručně.
Vzpomněli jste si?