NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
myVolts
Compact aluminium switch-mode unit delivers 24 V at 2 A (48 W) with overload, over-voltage and short-circuit protection for industrial, LED and 3D-printer use
The myVolts S-48-24 is a 48 W switch-mode unit that delivers 24 V at 2 A from a 100-240 V AC input. Its aluminium alloy case measures 85 x 58 x 33 mm and relies on natural convection for cooling. The supply suits industrial automation, LED displays, CCTV, 3D printers and similar engineering tasks.
Builders moving from larger linear supplies gain a smaller footprint and lower operating temperature. The jump is worthwhile when space is limited, when 0-40 °C ambient operation is required, or when CCC, FCC and CE marks are needed for compliance. The 100 % burn-in test adds confidence for continuous duty.
The ADJ terminal allows only minor voltage trimming, not a wide range. Overload, over-voltage and short-circuit protection shut the unit down rather than fold back current. Natural convection demands free airflow around the 33 mm height; sealed enclosures above 40 °C or loads above 2 A will exceed the design limits.
| Type | AT |
|---|
The supply measures 85 mm long, 58 mm wide and 33 mm high, with a natural-cooling aluminium chassis that fits standard DIN-rail or panel cut-outs matching those centres.
Connect live and neutral to the L and N pins for 100-240 V AC; the V terminal is +24 V and GND is 0 V — reversing V and GND is the frequent error that triggers the short-circuit protection.
At the rated 0-40 °C operating range the capacitors typically last several years; expect shorter life if the supply runs continuously near 40 °C or in 95 % humidity, so schedule a preventive swap after 3-5 years in harsh environments.
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?