APC
APC SMT3000RM2UC 3000VA 2U Rackmount UPS 120V
2U rackmount UPS delivers 2.7 kW or 3000 VA with LCD display and SmartConnect port for remote monitoring
- 3000 VA capacity keeps critical servers running
- 7 kW output powers dense rack loads
- 2U rackmount form fits standard cabinets
- 6 NEMA 5-15 plus 2 NEMA 5-20 outlets connect varied gear
- SmartSlot expansion adds network management cards
3000 VA Rackmount UPS for Server Rooms
The APC Smart-UPS SMT3000RM2UC is a 2U rackmount battery backup rated at 3000 VA and 2.7 kW. It delivers 120 V output with a ±5 % tolerance for connected servers, networking gear and storage arrays. The unit suits IT managers who need continuous power protection in standard 19-inch racks.
Six NEMA 5-15 and Two NEMA 5-20 Outlets
The rear panel provides six NEMA 5-15R and two NEMA 5-20R receptacles for mixed plug types. A single free SmartSlot accepts an optional network management card for remote monitoring. Connectivity includes USB, RS-232 and an emergency power off port. Operating noise is rated at 55 dBA between 32 °F and 104 °F.
Replaces Smaller Tower
At full load the battery sustains equipment for 2.8 minutes; at half load it extends to 10.8 minutes. Lower draws yield longer runtimes, such as 99 minutes at 200 W or 259 minutes at 50 W. Recharge completes in three hours. The jump is worth it when existing units cannot hold critical loads through typical outage windows.
I korthet
- 3000 VA capacity keeps critical servers running
- 7 kW output powers dense rack loads
- 2U rackmount form fits standard cabinets
- 6 NEMA 5-15 plus 2 NEMA 5-20 outlets connect varied gear
- SmartSlot expansion adds network management cards
Specifikationer
Inga publicerade specifikationer för den här produkten än.
Frågor om den här produkten
What management interfaces does the SMT3000RM2UC provide, and what does the USB port cap in practice?
The unit provides EPO, USB, and RS-232 management ports; the USB interface supports standard HID UPS monitoring and shutdown signalling for connected servers.
What physical mounting hardware is needed to install this 2U rackmount UPS?
The SMT3000RM2UC occupies 2U of 19-inch rack space and requires standard rack rails or shelf brackets rated for its weight; front-panel brackets are integrated.
How is the SmartConnect port configured during initial setup, and which step is commonly missed?
Connect the supplied USB or serial cable, register the device via the APC SmartConnect portal, then enable cloud monitoring; the step often missed is confirming the firmware update completes before placing the UPS under load.