Battery Technology Inc.
Battery Technology Inc. APCRBC152SLA152 server power supply 96 V DC
Sealed lead-acid battery pack delivers 96 V DC for compatible APC Smart-UPS SRT 3000 series units
- Reliable 96 V DC output for compatible APC Smart-UPS SRT units
- Sealed lead-acid chemistry eliminates routine fluid maintenance
- Direct replacement for APC RBC152 packs in listed SRT3000 models
- WEEE-certified design supports responsible end-of-life recycling
- Backed by an 18-month limited manufacturer warranty
Battery Pack for APC Smart-UPS SRT
The Battery Technology Inc. APCRBC152SLA152 is a sealed lead-acid battery pack that delivers 96 V DC to compatible APC Smart-UPS SRT units. It is designed for administrators who need to restore runtime on the listed SRT3000 models without replacing the entire UPS.
Thermals Noise and Power Draw
As a passive battery module it generates no audible noise and draws no power during standby or normal float charging. The sealed construction prevents electrolyte leakage and requires no active cooling in typical rack environments.
Sustained Load Behaviour
During extended discharge the pack supplies steady 96 V DC output until the UPS reaches its low-voltage cutoff, supporting critical loads for the full rated runtime. It is not intended for applications that demand hot-swappable modules or lithium-based chemistry.
Přednosti
- Reliable 96 V DC output for compatible APC Smart-UPS SRT units
- Sealed lead-acid chemistry eliminates routine fluid maintenance
- Direct replacement for APC RBC152 packs in listed SRT3000 models
- WEEE-certified design supports responsible end-of-life recycling
- Backed by an 18-month limited manufacturer warranty
Specifikace
Pro tento produkt zatím nejsou zveřejněny žádné specifikace.
Otázky k tomuto produktu
How do I install the APCRBC152SLA152 battery pack in my APC Smart-UPS SRT3000 series UPS?
Power down the UPS and disconnect it from mains. Remove the front panel, slide out the old battery tray, disconnect its cables noting polarity, connect the new pack's cables matching red to positive and black to negative, slide the tray back in, and replace the panel.
What maintenance or replacement will the APCRBC152SLA152 lead-acid battery pack need over time?
As a sealed lead-acid pack, it requires no watering. Plan to replace it every three to five years or when runtime drops below 80 % of original capacity. The 18-month limited warranty covers early defects.
What limit appears first when the APCRBC152SLA152 runs continuously at full load?
The 96 V DC output will sag as the cells deplete; runtime at maximum load is typically only a few minutes before the UPS initiates shutdown to protect the battery from deep discharge.