Eaton
Eaton 5SC1500 UPS 1500 VA 1080 W 120V Tower 8x NEMA 5-15R
A line-interactive UPS delivering 1500 VA and 1080 W through eight NEMA 5-15R outlets with USB and RS-232 management
- International Version120V
- Input Voltage Range96 - 144 Vac
- Input Frequency45-55 Hz (50 Hz system), 55-65 Hz (60 Hz system)
- Input ConnectionNEMA 5-15P
- VA Rating1440 VA
- Watts1080 watts
VA 1500 VA
- 500 VA
- 750 VA
- 1000 VA
- 1500 VA
Přeškrtnuté varianty existují, ale zde nejsou skladem.
- 1500 VA capacity supports critical equipment
- 1080 W output handles demanding power loads
- 13 minutes runtime at half load protects work
- USB and RS-232 ports enable management software
- Eight NEMA 5-15R outlets connect multiple devices
Desktop power protection
The Eaton 5SC1500 is a line-interactive tower UPS rated at 1500 VA and 1080 W for 120 V environments. It provides battery backup and surge protection for workstations, networking gear and peripherals through eight NEMA 5-15R outlets fed by a NEMA 5-15P input plug.
Home offices and small IT loads
This unit suits users who need USB and RS-232 connectivity for Eaton Intelligent Power Manager software and want a compact tower that fits on a desk or shelf. It is not for loads that exceed 1080 W, for sites without a NEMA 5-15P supply, or for installations that require rack mounting.
Runtime at full load
At full load the battery delivers five minutes of runtime, while half load provides thirteen minutes. This single figure determines whether the UPS gives enough time for an orderly shutdown of the connected equipment.
Přednosti
- 1500 VA capacity supports critical equipment
- 1080 W output handles demanding power loads
- 13 minutes runtime at half load protects work
- USB and RS-232 ports enable management software
- Eight NEMA 5-15R outlets connect multiple devices
Specifikace
| Brand | EATON |
|---|---|
| Model | 5SC1500 |
| International Version | 120V |
| Input Voltage Range | 96 - 144 Vac |
| Input Frequency | 45-55 Hz (50 Hz system), 55-65 Hz (60 Hz system) |
| Input Connection | NEMA 5-15P |
| VA Rating | 1440 VA |
| Watts | 1080 watts |
| Output Voltage | 120V |
| Outlets | 8 |
| Outlet Type | 8 x NEMA 5-15R |
| Battery Run Time | Run Time at Half Load: 13 mins Run Time at Full Load: 5 mins |
| Interface Port | RS-232, USB |
| Management Software | Eaton Intelligent Power Manager |
| Approvals | FCC Part 15 CISPR22 Class A / FCC part 15 Class A |
| Rackmountable | Not rack-mountable |
| Temperature | 0° to 40°C (32° to 104°F) |
| Humidity | 0-95% non-condensing |
| Dimensions | 8.20" x 5.90" x 16.10" |
| Weight | 34.00 lbs. |
| Package Contents | 5SC UPS User manual CD Eaton Intelligent Power Manager Software CD USB cable Serial Cable (RJ45 to DB9) Important Safety Instructions Limited Warranty Details |
| Přepravní hmotnost | 16.78 kg |
| Rozměry balení | 550 × 308 × 240 mm |
Další verze tohoto modelu
Dalších 1 v této řadě
Stejná řada, jiná paměť, chladič nebo takt — porovnejte, než se rozhodnete.
Otázky k tomuto produktu
Does the Eaton 5SC1500 need a NEMA 5-15P wall outlet to operate?
Yes, the unit ships with a NEMA 5-15P input plug and requires a standard 120 V NEMA 5-15R wall receptacle rated for at least 15 A.
Will the 5SC1500’s USB and RS-232 ports work with a legacy server that only has a serial console?
The UPS provides both USB and RS-232 interfaces; connect the RS-232 cable to the server’s serial port and use Eaton Intelligent Power Manager for monitoring.
How can I confirm the 5SC1500 is delivering battery backup after installation?
Pull the input plug while a load is attached; the UPS should continue powering the outlets and the management software will report on-battery status with the expected run time.
Také v této kategorii
Zákazníci také porovnávali
Stejná kategorie, stejná pokladna — osm měn a kurz zamčený na 30 minut.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case