Matrix
Matrix MPS-3600S-60-60 server power supply 3600W 60V 60A
Delivers up to 3600 W of adjustable DC power at 0-60 V and 0-60 A with PWM stability, MODBUS RTU remote control and full protection
- Single/RedundantMATRIX High-Power Lab Power Supply 3600W, 60V 60A
- Maximum Power3600 watts
- FansAir
- Output3600 watts
- Input Frequency Rangenot_applicable
- +12V RailsMATRIX High-Power Lab Power Supply 3600W, 60V 60A
- 3600 W output powers demanding lab and server loads
- Adjustable 0–60 V and 0–60 A covers wide test ranges
- 1 % F.S. accuracy ensures precise voltage and current delivery
- RS-485 and RS-232 with MODBUS RTU enable remote automation
- OVP, OCP, OTP and short-circuit protection safeguards connected equipment
High-power lab supply 3600W
The Matrix MPS-3600S-60-60 is a programmable DC power supply rated for 3600 watts with an adjustable output range of 0-60V and 0-60A. It accepts an AC input of 198Vac-242Vac at 50Hz and provides measurement accuracy of 0.1%F.S. This unit targets engineers and technicians who need a high-current bench source for development or test applications. It is not suited for buyers who require a standard ATX server PSU with 12V rails for rack-mounted equipment.
Sustained 3600W operation with air cooling
The supply uses PWM modulation and a high-gain amplification circuit designed for stable, reliable output during continuous operation. An intelligent temperature-controlled fan manages thermal load across the 14 in x 20 in x 10 in chassis weighing 27.6 pounds. Built-in protections include OVP, OCP, OTP and short-circuit safeguards to maintain safe parameters under prolonged heavy load. No liquid-cooling or redundant-module option is described in the specifications.
Bench installation with remote interfaces
The unit ships as a single piece of equipment ready for bench use with a 5-digit display showing up to three decimal places and front-panel preset buttons for voltage and current. RS-485 and RS-232 ports enable remote control via MODBUS RTU protocol for computer or PLC integration. A key-lock function prevents accidental parameter changes during operation. Installers must provide a suitable 198-242Vac supply; no rack-mount brackets or redundant-frame hardware are included.
Přednosti
- 3600 W output powers demanding lab and server loads
- Adjustable 0–60 V and 0–60 A covers wide test ranges
- 1 % F.S. accuracy ensures precise voltage and current delivery
- RS-485 and RS-232 with MODBUS RTU enable remote automation
- OVP, OCP, OTP and short-circuit protection safeguards connected equipment
Specifikace
| Brand | MATRIX |
|---|---|
| Series | 60V 60A, MPS-3600S-60-60 |
| Model | 60V 60A |
| Part Number | MPS-3600S-60-60 |
| Single/Redundant | MATRIX High-Power Lab Power Supply 3600W, 60V 60A |
| Maximum Power | 3600 watts |
| Fans | Air |
| Output | 3600 watts |
| Input Frequency Range | not_applicable |
| +12V Rails | MATRIX High-Power Lab Power Supply 3600W, 60V 60A |
| PFC | MATRIX High-Power Lab Power Supply 3600W, 60V 60A |
| Dimensions | 14 in x 20 in x 10 in |
| Weight | 27.6 pounds |
| Package Contents | MATRIX High-Power Lab Power Supply 3600W, 60V 60A x 1 |
Otázky k tomuto produktu
How loud and hot does the MPS-3600S-60-60 get when it runs continuously at 3600 W?
The unit uses an air-cooled fan system; the manufacturer specifies an intelligent temperature-control fan that adjusts speed with load, but no decibel or exhaust-temperature figures are published.
What AC supply must already be on site for the MPS-3600S-60-60 to operate?
The supply requires a 198-242 Vac, 50 Hz single-phase source; ensure the circuit and connector can deliver the rated input current for 3600 W output.
Can the MPS-3600S-60-60 be controlled alongside legacy RS-232 or RS-485 equipment?
Yes, it provides both RS-232 and RS-485 ports using the MODBUS RTU protocol, so it can share a bus or be addressed with older PLCs and PCs.
Také v této kategorii
Zákazníci také porovnávali
Stejná kategorie, stejná pokladna — osm měn a kurz zamčený na 30 minut.



