Tripp Lite SU3000LCD2UHVTF 3000VA 2700W 208/120V UPS
A 2U double-conversion UPS delivers 3000VA and 2700W of pure sine-wave power with zero transfer time, .9 power factor and 570 joules surge suppression.
- Battery TypeValve Regulated Lead Acid (VRLA)
- Zero transfer time protects critical equipment
- Double-conversion delivers pure sine wave output
- Selectable strategies match efficiency to priority
- Built-in step-down transformer supports 208V and 120V loads
- 570 joules surge suppression shields connected devices
SmartOnline Double-Conversion UPS
The Tripp Lite SU3000LCD2UHVTF is a 3000VA double-conversion UPS delivering 2700W with a .9 power factor. It provides pure sine wave output and zero transfer time for critical network closet, computer room and data center equipment.
Included Step-Down Transformer
A 2U step-down transformer is included so this 208V and 120V 60 Hz UPS can support both low- and high-voltage equipment simultaneously. Four selectable power strategies let you prioritise maximum efficiency, maximum quality, frequency regulation or automatic adaptive operation.
VRLA Battery Constraints
The valve regulated lead acid battery chemistry requires regular maintenance cycles and eventual replacement as capacity degrades over time. Surge suppression is rated at 570 joules, which protects against typical transients but not sustained over-voltage events or direct lightning strikes.
Přednosti
- Zero transfer time protects critical equipment
- Double-conversion delivers pure sine wave output
- Selectable strategies match efficiency to priority
- Built-in step-down transformer supports 208V and 120V loads
- 570 joules surge suppression shields connected devices
Specifikace
| Brand | TRIPP LITE |
|---|---|
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Přepravní hmotnost | 87.09 kg |
| Rozměry balení | 1219 × 1016 × 959 mm |
Otázky k tomuto produktu
How often will the valve regulated lead acid battery need replacement?
The internal VRLA battery typically lasts three to five years before capacity drops enough to require a new cartridge.
What limits continuous output when the unit runs at full load?
The 2.7 kW real power rating is the ceiling; sustained draw above that trips overload protection.
How much heat and fan noise should I expect during all day operation?
Double conversion runs the inverter continuously so the fans stay active and the chassis exhausts warm air steadily.