Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
myVolts
A regulated 12V 10A PWM power supply with delayed power-off and natural cooling for access control systems
The myVolts 12V-10A-9CH is a PWM regulated power supply box designed for access control systems. It delivers a constant 12 V output at 10 A with a delayed power off function. The unit uses full bridge topology and operates from a 100-260 V input. Vertical mounting makes installation and removal straightforward.
Natural cooling eliminates fan noise while maintaining an 85 percent working efficiency across the 50-60 Hz operating range. The supply tolerates ambient temperatures from -20 to 80 degrees without active airflow. Output ripple noise is specified at 45 mpv with voltage and load regulation each held to 1 percent. CE certification confirms compliance for the intended access control scope.
The vertical form factor suits cabinet or wall mounting where horizontal space is limited. A 240 W output capacity supports multiple access devices from a single unit. Delayed power off preserves lock state during brief mains interruptions. Buyers needing higher current, redundant inputs or rack mount brackets will need a different solution.
| Type | AT |
|---|
Mount the box vertically using the supplied accessories; the step often missed is securing all mounting points so the natural-cooling airflow path stays clear.
Periodically vacuum dust from the ventilation slots to keep the natural-cooling path effective; the internal UPS battery will eventually require replacement.
The 240 W output power ceiling is reached first; sustained 10 A at 12 V will hit this limit before the 80 °C operating temperature boundary.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?