NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Prijímame kryptomeny — takže mince, ktoré držíte, môžete zameniť za skutočný hardvér.Plaťte v krypte, miňte ho na skutočný hardvér. Poistená doprava zadarmo po celom svete nad 399 $. Neutrálne kartóny bez potlače, odosielané z Nemecka.Poistená doprava zadarmo nad 399 $. Váš kurz je zablokovaný na 30 minút hneď po otvorení pokladne.Kurz zablokovaný na 30 minút. Každý produkt je zapečatený, jeho sériové číslo je overené a vzťahuje sa naň 24-mesačná záruka.Zapečatené, 24-mesačná záruka.
myVolts
A regulated 12V 10A PWM power supply with delayed power-off and natural cooling for access control systems
The myVolts 12V-10A-9CH is a PWM regulated power supply box designed for access control systems. It delivers a constant 12 V output at 10 A with a delayed power off function. The unit uses full bridge topology and operates from a 100-260 V input. Vertical mounting makes installation and removal straightforward.
Natural cooling eliminates fan noise while maintaining an 85 percent working efficiency across the 50-60 Hz operating range. The supply tolerates ambient temperatures from -20 to 80 degrees without active airflow. Output ripple noise is specified at 45 mpv with voltage and load regulation each held to 1 percent. CE certification confirms compliance for the intended access control scope.
The vertical form factor suits cabinet or wall mounting where horizontal space is limited. A 240 W output capacity supports multiple access devices from a single unit. Delayed power off preserves lock state during brief mains interruptions. Buyers needing higher current, redundant inputs or rack mount brackets will need a different solution.
| Type | AT |
|---|
Mount the box vertically using the supplied accessories; the step often missed is securing all mounting points so the natural-cooling airflow path stays clear.
Periodically vacuum dust from the ventilation slots to keep the natural-cooling path effective; the internal UPS battery will eventually require replacement.
The 240 W output power ceiling is reached first; sustained 10 A at 12 V will hit this limit before the 80 °C operating temperature boundary.
Aj v tomto oddelení
Rovnaké oddelenie, rovnaká pokladňa — osem mien a kurz zablokovaný na 30 minút.
Mena, v ktorej platíte, a mena, v ktorej sa zobrazujú ceny.
Odoslané z vašej peňaženky na pokladni
Len na zobrazenie — katalóg je uvedený v dolároch
Žiadna mena nezodpovedá.
Vyberte jazyk, v ktorom s vami bude web komunikovať.
Ste tu prvýkrát?
Účet už máte?
Automatický reset hesla neexistuje: tento obchod neposiela žiadne e-maily, takže neexistuje jednorazový odkaz, o ktorý by ste mohli požiadať. Nechajte adresu na účte — niekto sa jej ujme ručne.
Žiadosť zaznamenaná
Do vašej schránky nič nepríde — tento obchod neposiela vôbec žiadne e-maily. Niekto sa o to postará ručne.
Spomenuli ste si?