NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Accettiamo criptovalute — così le crypto che Lei possiede possono comprare hardware reale.Paghi in crypto, la spenda in hardware reale. Spedizione assicurata gratuita in tutto il mondo oltre i 399 $. Cartoni neutri, senza marchio, spediti dalla Germania.Spedizione assicurata gratuita oltre i 399 $. Il Suo tasso resta bloccato per 30 minuti dall’apertura del checkout.Tasso bloccato 30 minuti. Ogni articolo è sigillato, il numero di serie è verificato, ed è coperto da una garanzia di 24 mesi.Sigillato, garantito 24 mesi.
KHACHIMO
2U server power supply delivering 510W ATX power for rack-mounted systems
The KHACHIMO HK600-12UEPP delivers 510 W of continuous power in a 2U form factor built for rack-mount servers. It fits standard ATX wiring so it can replace compatible units in existing chassis. The supply is intended for system integrators and IT teams who need a tested, ready-to-install replacement for 12 V-heavy server loads.
The unit operates from a 12 V primary rail rated at 600 W peak, with the 510 W label reflecting sustained output under typical server workloads. Internal fan speed ramps with load and inlet temperature, keeping component temperatures within spec during normal operation. Acoustic output rises with fan speed but remains within expectations for a 2U rack enclosure.
Each unit is verified as test working before it leaves the supplier, reducing the chance of a dead-on-arrival replacement. No extra cables, mounting rails or management software are bundled with the power supply itself. Buyers who need redundant hot-swap modules or additional cable kits must source those separately.
| Type | ATX |
|---|
Mount the unit in the 2U chassis bay, secure all four screws, then connect the 24-pin ATX and CPU power cables; the step most often missed is fully seating the main power connector until the latch clicks.
Clean the intake fan and heatsink every 6–12 months to prevent dust build-up; plan to replace the entire supply once the internal electrolytic capacitors reach their rated service life.
The 510 W continuous power rating is reached before the 600 W peak rating, so total system draw must stay at or below 510 W for stable long-term operation.
Anche in questo reparto
Stesso reparto, stessa cassa — otto monete e un cambio bloccato per 30 minuti.
Cosa invia per pagare, e in quale valuta legge i prezzi.
Inviato dal Suo portafoglio alla cassa
Solo a titolo indicativo — il catalogo è espresso in dollari
Nessuna valuta corrisponde.
Scelga la lingua in cui il sito Le parla.
Prima visita?
Ne ha già uno?
Non esiste un ripristino automatico: questo negozio non invia e-mail, quindi non esiste alcun link monouso da richiedere. Lasci l’indirizzo sull’account: verrà gestito manualmente.
Richiesta registrata
Non arriverà nulla nella Sua casella di posta — questo negozio non invia e-mail. Qualcuno se ne occupa manualmente.
L’ha ritrovata?