Liebert
Liebert MP2-120E MicroPOD 5-Outlets PDU 120V
Rack-mountable 5-outlet PDU with one L5-20R and four 5-15/20R receptacles for 120V UPS bypass
- TypePDUs & Line Conditioners
- FeaturesForm Factor:Rack-mountable Product Type:PDU Form Factor:Rack
- Maintenance bypass keeps connected equipment powered during UPS service
- 2U rack-mountable form factor fits standard server cabinets
- Five output receptacles include one NEMA L5-20R and four NEMA 5-15/20R
- Designed for 120 V Liebert UPS systems
- New condition, first listed by the manufacturer in 2025
Product identity
The Liebert MP2-120E is a rack-mountable power distribution unit designed for 120V environments. It provides maintenance bypass capability for compatible Liebert UPS systems while delivering power through five output receptacles.
Suitability
This unit suits operators who need to service a 120V UPS without interrupting connected loads. It is not for operators running infrastructure at other voltages or those requiring receptacle types beyond the single NEMA L5-20R and four NEMA 5-15/20R outputs provided.
Deciding specification
The 120V input rating is the specification that determines whether this MicroPOD matches the installation. Only sites with a 120V supply and a compatible Liebert UPS can use this bypass module.
Punti di forza
- Maintenance bypass keeps connected equipment powered during UPS service
- 2U rack-mountable form factor fits standard server cabinets
- Five output receptacles include one NEMA L5-20R and four NEMA 5-15/20R
- Designed for 120 V Liebert UPS systems
- New condition, first listed by the manufacturer in 2025
Caratteristiche tecniche
| Brand | Liebert |
|---|---|
| Type | PDUs & Line Conditioners |
| Features | Form Factor:Rack-mountable Product Type:PDU Form Factor:Rack-mountable Product Name:MicroPOD 5-Outlets PDU Output Receptacles:1 x NEMA L5-20R 4 x NEMA 5-15/20R |
| Peso di spedizione | 4.40 kg |
| Dimensioni del pacco | 465 × 210 × 170 mm |
Domande su questo articolo
What output standard do the NEMA L5-20R and 5-15/20R receptacles cap at for this MicroPOD?
The single L5-20R outlet is rated for 20 A at 120 V, while the four 5-15/20R outlets accept either 15 A or 20 A plugs at the same voltage.
What physical mounting does the 2U rack-mountable chassis require?
It occupies 2U of vertical space in a standard rack and secures with front-panel mounting ears.
How is the bypass switch wired during installation, and which step is often missed?
The UPS input and output cables must land on the correct MicroPOD terminals before the rotary switch is turned; reversing them leaves the load unprotected.
Anche in questo reparto
Anche i clienti hanno confrontato questi
Stesso reparto, stessa cassa — otto monete e un cambio bloccato per 30 minuti.
TRENDnet TC-NT2 Cable Tester for Ethernet, Coax, USB and Token Ring
- Tests Pin Configura…
- 99164H
FLUKE networks 10061501 D914S Impact Tool pc tool
- Idustry standard, i…
- D914S 10061501 Impa…