Accettiamo criptovalute — così le crypto che Lei possiede possono comprare hardware reale.Paghi in crypto, la spenda in hardware reale. Spedizione assicurata gratuita in tutto il mondo oltre i 399 $. Cartoni neutri, senza marchio, spediti dalla Germania.Spedizione assicurata gratuita oltre i 399 $. Il Suo tasso resta bloccato per 30 minuti dall’apertura del checkout.Tasso bloccato 30 minuti. Ogni articolo è sigillato, il numero di serie è verificato, ed è coperto da una garanzia di 24 mesi.Sigillato, garantito 24 mesi.

Articoli preferiti Accedi

Other Electricities

Other Electricities 100M LC-LC Duplex Armored Fiber Patch Cable

SKU CH-FAC9-GN8PW

Armored duplex fiber patch cable with LC UPC connectors and 9/125µm single-mode fiber, rated for -40°C to 75°C operation

  • TypeRack
  • Armored stainless-steel tube shields fibers from rodents and crushing
  • Duplex LC UPC connectors deliver 0.3 dB insertion loss
  • 9/125 µm single-mode fiber supports long-distance links
  • Withstands -40 °C to 75 °C operating extremes
  • Dynamic bend radius of 30D eases conduit pulls

Armored Fiber Patch Cable

This 100-meter duplex cable uses LC UPC connectors on both ends and a 9/125 µm single-mode fiber. The stainless-steel tube and PVC jacket protect the fibers in conduit, underground or outdoor runs where dust, moisture, oil, gas or rodents are present.

Single-Mode 9/125 µm Fiber

The fiber mode is the specification that determines compatibility; this cable only works with single-mode transceivers and links designed for 9/125 µm cores. Using it with multimode equipment will cause high loss or complete link failure.

Rugged Build with Defined Bend Limit

The armored jacket makes the cable heavier and stiffer than standard patch cords, so allow extra space in trays and conduits. Respect the minimum dynamic bending radius of 30D to avoid increased insertion loss above .3 dB or fiber damage during installation.

Punti di forza

  • Armored stainless-steel tube shields fibers from rodents and crushing
  • Duplex LC UPC connectors deliver 0.3 dB insertion loss
  • 9/125 µm single-mode fiber supports long-distance links
  • Withstands -40 °C to 75 °C operating extremes
  • Dynamic bend radius of 30D eases conduit pulls

Caratteristiche tecniche

TypeRack

Domande su questo articolo

What does 0.3 dB insertion loss mean for a live link?

It adds very little signal attenuation so the link budget is barely affected by the patch cable itself.

What does the LC UPC duplex interface limit in practice?

The LC UPC duplex connectors mate with standard LC ports and the 9/125 µm single-mode fiber carries both transmit and receive paths over one jacket.

What clearance does the armored jacket need to bend without damage?

The dynamic bend radius is 30 times the cable diameter so allow at least that radius when routing through conduit or trays.

Anche in questo reparto

Anche i clienti hanno confrontato questi

Stesso reparto, stessa cassa — otto monete e un cambio bloccato per 30 minuti.