Mēs pieņemam kriptovalūtu — lai tā, kas Jums pieder, varētu nopirkt īstu aparatūru.Maksājiet kriptovalūtā, iztērējiet to īstai aparatūrai. Bezmaksas apdrošināta piegāde visā pasaulē virs 399 $. Vienkāršas, nemarķētas kastes, sūtītas no Vācijas.Bezmaksas apdrošināta piegāde virs 399 $. Jūsu kurss tiek fiksēts uz 30 minūtēm, tiklīdz atveras kase.Kurss fiksēts uz 30 minūtēm. Katra prece ir aizzīmogota, tās sērijas numurs ir pārbaudīts, un uz to attiecas 24 mēnešu garantija.Aizzīmogots, 24 mēnešu garantija.
myVolts
A continuously adjustable 0-60V, 0-5A DC power supply with CV/CC auto-switching, dual voltage and current displays, and short-circuit, over-temperature, and current-limiting protection
The myVolts STP6005D is a bench-top unit that delivers continuously adjustable DC output from 0 to 60 volts and 0 to 5 amps. It operates in automatic constant-voltage or constant-current modes, making it suited for factory maintenance, calibration stations and integration into test equipment cabinets. Dual independent displays show voltage and current at a glance.
The supply runs from 0 to 40 degrees Celsius with up to 80 percent relative humidity and achieves up to 80 percent efficiency. Protection includes current-limiting buck, short-circuit and over-temperature safeguards. A 5 A 250 VAC fuse protects the input side while ripple and noise stay at 50 mVrms and 50 mArms across the specified bandwidth.
The AT-type form factor fits standard equipment racks and cabinets without requiring proprietary mounting hardware. Continuous CV/CC adjustment frees the user from swapping fixed-voltage modules during prototyping or repair work. Regulation holds at 0.5 percent plus 3 mV for voltage and 0.2 percent plus 3 mA for current, with a 300 ps recovery time for transient loads.
| Type | AT |
|---|
Mount the unit in a test cabinet, connect to a 250VAC source with the F5AL fuse fitted, then set the 0-60V and 0-5A limits before enabling output. The step often missed is verifying the CV/CC automatic changeover works at the 3A boundary.
Replace the F5AL 250VAC fuse if it blows. Keep ventilation clear so the 0-40°C operating range and 80% efficiency are maintained; no other user-serviceable parts are indicated.
The 40°C working-temperature ceiling is reached before the 60V or 5A electrical limits, triggering over-temperature protection and shutting the output down.
Arī šajā sadaļā
Tas pats plaukts, tā pati kase — astoņas kriptovalūtas un kursa fiksēšana uz 30 minūtēm.
Kriptovalūta, kurā maksājat, un valūta, kurā redzat cenas.
Nosūtīts no Jūsu maciņa, noformējot pasūtījumu
Tikai informatīvi — katalogā cenas norādītas ASV dolāros
Neviena valūta neatbilst.
Izvēlieties valodu, kurā vietne sarunājas ar Jums.
Pirmo reizi šeit?
Jau ir konts?
Automātiskas atiestatīšanas nav: šis veikals nesūta e-pastus, tāpēc nav arī vienreizējas saites, ko pieprasīt. Atstājiet adresi kontā, un tā tiks apstrādāta manuāli.
Pieprasījums saņemts
Uz Jūsu e-pastu nekas neatnāks — šis veikals vispār nesūta e-pastus. Kāds šos pieprasījumus apstrādā manuāli.
Atcerējāties?