Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.
myVolts
A continuously adjustable 0-60V, 0-5A DC power supply with CV/CC auto-switching, dual voltage and current displays, and short-circuit, over-temperature, and current-limiting protection
The myVolts STP6005D is a bench-top unit that delivers continuously adjustable DC output from 0 to 60 volts and 0 to 5 amps. It operates in automatic constant-voltage or constant-current modes, making it suited for factory maintenance, calibration stations and integration into test equipment cabinets. Dual independent displays show voltage and current at a glance.
The supply runs from 0 to 40 degrees Celsius with up to 80 percent relative humidity and achieves up to 80 percent efficiency. Protection includes current-limiting buck, short-circuit and over-temperature safeguards. A 5 A 250 VAC fuse protects the input side while ripple and noise stay at 50 mVrms and 50 mArms across the specified bandwidth.
The AT-type form factor fits standard equipment racks and cabinets without requiring proprietary mounting hardware. Continuous CV/CC adjustment frees the user from swapping fixed-voltage modules during prototyping or repair work. Regulation holds at 0.5 percent plus 3 mV for voltage and 0.2 percent plus 3 mA for current, with a 300 ps recovery time for transient loads.
| Type | AT |
|---|
Mount the unit in a test cabinet, connect to a 250VAC source with the F5AL fuse fitted, then set the 0-60V and 0-5A limits before enabling output. The step often missed is verifying the CV/CC automatic changeover works at the 3A boundary.
Replace the F5AL 250VAC fuse if it blows. Keep ventilation clear so the 0-40°C operating range and 80% efficiency are maintained; no other user-serviceable parts are indicated.
The 40°C working-temperature ceiling is reached before the 60V or 5A electrical limits, triggering over-temperature protection and shutting the output down.
Ook in deze afdeling
Dezelfde afdeling, dezelfde kassa — acht munten en een koers die 30 minuten vaststaat.
Waarmee u betaalt, en waarin u de prijzen leest.
Verzonden vanuit uw wallet bij het afrekenen
Alleen ter weergave — de catalogus is geprijsd in USD
Geen valuta gevonden.
Kies de taal waarin de site met u spreekt.
Nieuw hier?
Al een account?
Er is geen automatisch herstel: deze winkel verstuurt geen e-mail, dus er is geen eenmalige link om aan te vragen. Laat het adres op het account achter en het wordt handmatig opgepakt.
Verzoek genoteerd
Er is niets onderweg naar uw inbox — deze winkel verstuurt helemaal geen e-mail. Iemand pakt dit handmatig op.
Weet u het weer?