Acceptăm criptomonede — astfel, criptomonedele pe care le dețineți pot cumpăra echipamente reale.Plătiți în cripto, cheltuiți-o pe echipamente reale. Livrare asigurată gratuită oriunde în lume peste 399 $. Cartoane neutre, fără marcă, expediate din Germania.Livrare asigurată gratuită peste 399 $. Cursul dumneavoastră este blocat timp de 30 de minute de la deschiderea paginii de plată.Curs blocat 30 de minute. Fiecare articol este sigilat, numărul de serie este verificat, iar produsul este acoperit de o garanție de 24 de luni.Sigilat, garantat 24 de luni.
myVolts
A continuously adjustable 0-60V, 0-5A DC power supply with CV/CC auto-switching, dual voltage and current displays, and short-circuit, over-temperature, and current-limiting protection
The myVolts STP6005D is a bench-top unit that delivers continuously adjustable DC output from 0 to 60 volts and 0 to 5 amps. It operates in automatic constant-voltage or constant-current modes, making it suited for factory maintenance, calibration stations and integration into test equipment cabinets. Dual independent displays show voltage and current at a glance.
The supply runs from 0 to 40 degrees Celsius with up to 80 percent relative humidity and achieves up to 80 percent efficiency. Protection includes current-limiting buck, short-circuit and over-temperature safeguards. A 5 A 250 VAC fuse protects the input side while ripple and noise stay at 50 mVrms and 50 mArms across the specified bandwidth.
The AT-type form factor fits standard equipment racks and cabinets without requiring proprietary mounting hardware. Continuous CV/CC adjustment frees the user from swapping fixed-voltage modules during prototyping or repair work. Regulation holds at 0.5 percent plus 3 mV for voltage and 0.2 percent plus 3 mA for current, with a 300 ps recovery time for transient loads.
| Type | AT |
|---|
Mount the unit in a test cabinet, connect to a 250VAC source with the F5AL fuse fitted, then set the 0-60V and 0-5A limits before enabling output. The step often missed is verifying the CV/CC automatic changeover works at the 3A boundary.
Replace the F5AL 250VAC fuse if it blows. Keep ventilation clear so the 0-40°C operating range and 80% efficiency are maintained; no other user-serviceable parts are indicated.
The 40°C working-temperature ceiling is reached before the 60V or 5A electrical limits, triggering over-temperature protection and shutting the output down.
Tot din acest raion
Același raion, aceeași finalizare a comenzii — opt monede și un curs blocat 30 de minute.
În ce monedă plătiți și în ce monedă citiți prețurile.
Trimis din portofelul dumneavoastră la finalizarea comenzii
Doar pentru afișare — catalogul este exprimat în dolari
Nicio monedă nu corespunde.
Alegeți limba în care vă vorbește site-ul.
Prima vizită?
Aveți deja un cont?
Nu există o resetare automată: acest magazin nu trimite niciun e-mail, deci nu există niciun link de unică folosință de solicitat. Lăsați adresa în cont. Va fi tratată manual.
Cerere înregistrată
Nu veți primi nimic în căsuța de e-mail — acest magazin nu trimite niciun e-mail. Cineva se ocupă de asta manual.
V-ați amintit-o?