Accettiamo criptovalute — così le crypto che Lei possiede possono comprare hardware reale.Paghi in crypto, la spenda in hardware reale. Spedizione assicurata gratuita in tutto il mondo oltre i 399 $. Cartoni neutri, senza marchio, spediti dalla Germania.Spedizione assicurata gratuita oltre i 399 $. Il Suo tasso resta bloccato per 30 minuti dall’apertura del checkout.Tasso bloccato 30 minuti. Ogni articolo è sigillato, il numero di serie è verificato, ed è coperto da una garanzia di 24 mesi.Sigillato, garantito 24 mesi.
myVolts
A continuously adjustable 0-60V, 0-5A DC power supply with CV/CC auto-switching, dual voltage and current displays, and short-circuit, over-temperature, and current-limiting protection
The myVolts STP6005D is a bench-top unit that delivers continuously adjustable DC output from 0 to 60 volts and 0 to 5 amps. It operates in automatic constant-voltage or constant-current modes, making it suited for factory maintenance, calibration stations and integration into test equipment cabinets. Dual independent displays show voltage and current at a glance.
The supply runs from 0 to 40 degrees Celsius with up to 80 percent relative humidity and achieves up to 80 percent efficiency. Protection includes current-limiting buck, short-circuit and over-temperature safeguards. A 5 A 250 VAC fuse protects the input side while ripple and noise stay at 50 mVrms and 50 mArms across the specified bandwidth.
The AT-type form factor fits standard equipment racks and cabinets without requiring proprietary mounting hardware. Continuous CV/CC adjustment frees the user from swapping fixed-voltage modules during prototyping or repair work. Regulation holds at 0.5 percent plus 3 mV for voltage and 0.2 percent plus 3 mA for current, with a 300 ps recovery time for transient loads.
| Type | AT |
|---|
Mount the unit in a test cabinet, connect to a 250VAC source with the F5AL fuse fitted, then set the 0-60V and 0-5A limits before enabling output. The step often missed is verifying the CV/CC automatic changeover works at the 3A boundary.
Replace the F5AL 250VAC fuse if it blows. Keep ventilation clear so the 0-40°C operating range and 80% efficiency are maintained; no other user-serviceable parts are indicated.
The 40°C working-temperature ceiling is reached before the 60V or 5A electrical limits, triggering over-temperature protection and shutting the output down.
Anche in questo reparto
Stesso reparto, stessa cassa — otto monete e un cambio bloccato per 30 minuti.
Cosa invia per pagare, e in quale valuta legge i prezzi.
Inviato dal Suo portafoglio alla cassa
Solo a titolo indicativo — il catalogo è espresso in dollari
Nessuna valuta corrisponde.
Scelga la lingua in cui il sito Le parla.
Prima visita?
Ne ha già uno?
Non esiste un ripristino automatico: questo negozio non invia e-mail, quindi non esiste alcun link monouso da richiedere. Lasci l’indirizzo sull’account: verrà gestito manualmente.
Richiesta registrata
Non arriverà nulla nella Sua casella di posta — questo negozio non invia e-mail. Qualcuno se ne occupa manualmente.
L’ha ritrovata?