Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.
myVolts
A continuously adjustable 0-60V, 0-5A DC power supply with CV/CC auto-switching, dual voltage and current displays, and short-circuit, over-temperature, and current-limiting protection
The myVolts STP6005D is a bench-top unit that delivers continuously adjustable DC output from 0 to 60 volts and 0 to 5 amps. It operates in automatic constant-voltage or constant-current modes, making it suited for factory maintenance, calibration stations and integration into test equipment cabinets. Dual independent displays show voltage and current at a glance.
The supply runs from 0 to 40 degrees Celsius with up to 80 percent relative humidity and achieves up to 80 percent efficiency. Protection includes current-limiting buck, short-circuit and over-temperature safeguards. A 5 A 250 VAC fuse protects the input side while ripple and noise stay at 50 mVrms and 50 mArms across the specified bandwidth.
The AT-type form factor fits standard equipment racks and cabinets without requiring proprietary mounting hardware. Continuous CV/CC adjustment frees the user from swapping fixed-voltage modules during prototyping or repair work. Regulation holds at 0.5 percent plus 3 mV for voltage and 0.2 percent plus 3 mA for current, with a 300 ps recovery time for transient loads.
| Type | AT |
|---|
Mount the unit in a test cabinet, connect to a 250VAC source with the F5AL fuse fitted, then set the 0-60V and 0-5A limits before enabling output. The step often missed is verifying the CV/CC automatic changeover works at the 3A boundary.
Replace the F5AL 250VAC fuse if it blows. Keep ventilation clear so the 0-40°C operating range and 80% efficiency are maintained; no other user-serviceable parts are indicated.
The 40°C working-temperature ceiling is reached before the 60V or 5A electrical limits, triggering over-temperature protection and shutting the output down.
Også i denne avdelingen
Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.
Det du betaler med, og det du ser prisene i.
Sendes fra lommeboken din i kassen
Kun visning — katalogen er prissatt i USD
Fant ingen valuta.
Velg språket nettstedet snakker til deg på.
Ny her?
Har du allerede en konto?
Det finnes ingen automatisk tilbakestilling: butikken sender ikke e-post, så det finnes ingen engangslenke å be om. La adressen stå på kontoen, så blir den behandlet manuelt.
Forespørsel registrert
Ingenting er på vei til innboksen din — butikken sender ingen e-post i det hele tatt. Noen behandler dette manuelt.
Husket du det likevel?