Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.

Favoriete artikelen Inloggen

LHM

LHM HTK600-12C21 600 W 12 V 50 A power supply

SKU CH-19G4-QK9QM MPN HTK600-12C21

Enclosed switching unit delivers 600 W at 12 V and 50 A from a 90-264 VAC input

  • 600 W output powers demanding 12 V equipment
  • Wide 90 to 264 VAC input suits global mains supplies
  • Single 12 V rail delivers up to 50 A continuous current
  • EN60950-1 approval confirms safety compliance
  • Enclosed 9.17 × 4.29 × 2.5 in chassis simplifies mounting

Product identity

The LHM HTK600-12C21 is an enclosed 600 W switching power supply that delivers a single 12 V output at 50 A. It accepts a wide 90 VAC to 264 VAC input range and meets EN60950-1 safety approval. The chassis-mount unit measures 9.17 in by 4.29 in by 2.5 in and is RoHS compliant.

Suitability

This unit suits engineers and integrators building industrial or commercial equipment that requires a regulated 12 V rail up to 600 W in a compact enclosed chassis. Buyers who need multiple output voltages, a different output voltage, or higher total power should look at other models.

Deciding specification

The single 12 V output rated at 50 A is the specification that determines whether this supply matches the load. Verify that the equipment draws no more than 600 W at 12 V and that the chassis-mount footprint fits the enclosure.

Pluspunten

  • 600 W output powers demanding 12 V equipment
  • Wide 90 to 264 VAC input suits global mains supplies
  • Single 12 V rail delivers up to 50 A continuous current
  • EN60950-1 approval confirms safety compliance
  • Enclosed 9.17 × 4.29 × 2.5 in chassis simplifies mounting

Specificaties

Voor dit artikel zijn nog geen specificaties gepubliceerd.

Vragen over dit artikel

How do I mount the HTK600-12C21 in a chassis and what clearance mistake do installers make?

Use the four mounting holes on the 9.17 in by 4.29 in base; the most common error is blocking the 2.5 in height above the unit, which restricts airflow through the enclosed case.

Which component will need replacement first during continuous 50 A operation?

The internal electrolytic capacitors on the 12 V rail degrade fastest under sustained 600 W load and elevated temperature.

What thermal limit appears first when the supply runs at 600 W for long periods?

The enclosed chassis reaches its maximum safe internal temperature before the 90-264 VAC input or 12 V 50 A output limits are hit.