Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.

Overvåkingsliste Logg inn

ICY DOCK

ICY DOCK ToughArmor MB105VP-B 2 Bay U.2/U.3 NVMe 5.25 Rack

SKU CH-WHV3-4WEDF

Holds two 2.5-inch U.2/U.3 NVMe SSDs up to 15mm height in a 5.25-inch bay with a 40mm cooling fan and 64Gb/s PCIe 4.0 via Slimline SAS

  • TypeRack
  • Fits two 2.5-inch U.2/U.3 NVMe SSDs up to 15mm height in one 5.25-inch bay
  • Connects via single Slimline SAS SFF-8654-8i for PCIe 4.0 speeds up to 64Gb/s per bay
  • Eagle-hook latch keeps trays locked during vibration or transport
  • Three-speed 40mm rear fan with Hi, Low, Off settings cools drives through ventilation holes
  • Front-access removable trays make drive swaps fast without tools

Dual U.2/U.3 NVMe rack for 5.25 bay

The ToughArmor MB105VP-B installs into a standard external 5.25-inch optical drive bay and holds two 2.5-inch U.2 or U.3 PCIe NVMe SSDs up to 15mm drive height. It connects both drives through a single Slimline SAS SFF-8654-8i connector for PCIe 4.0 data paths. Removable full-metal trays with an eagle-hook latch allow front-access drive swaps without tools.

Full-metal enclosure with adjustable cooling

The all-metal chassis uses a built-in 40mm x 20mm rear fan that exhausts heat through ventilation holes above the trays. Three fan settings — Hi, Low and Off — let the operator match airflow to workload intensity. The tray design adds cooling space above each drive to improve heat dissipation during sustained operation.

PCIe 4.0 bandwidth shared over one Slimline SAS link

Each bay supports PCIe 4.0 specification with transfer rates up to 64Gb/s, but both drives share the single SFF-8654-8i connection to the host. Total throughput depends on the host controller lane allocation and cable length. Builders needing more than two U.2/U.3 devices or separate controller links will require additional enclosures or a different backplane topology.

Høydepunkter

  • Fits two 2.5-inch U.2/U.3 NVMe SSDs up to 15mm height in one 5.25-inch bay
  • Connects via single Slimline SAS SFF-8654-8i for PCIe 4.0 speeds up to 64Gb/s per bay
  • Eagle-hook latch keeps trays locked during vibration or transport
  • Three-speed 40mm rear fan with Hi, Low, Off settings cools drives through ventilation holes
  • Front-access removable trays make drive swaps fast without tools

Spesifikasjoner

TypeRack

Spørsmål om denne varen

What is the maximum transfer rate per bay over the Slimline SAS (SFF-8654-8i) interface?

Each drive bay supports PCIe 4.0 with transfer rates up to 64Gb/s through the single Slimline SAS (SFF-8654-8i) connector.

What drive dimensions and bay clearance does the enclosure require?

It accepts two 2.5-inch U.2/U.3 NVMe SSDs up to 15mm height and installs into a standard external 5.25-inch optical drive bay.

How are the drives inserted and what common step should be avoided?

Drives mount into the two EZ Slide Mini trays which slide into the front; the eagle-hook latch on each tray must be fully engaged to secure the drive.

Også i denne avdelingen

Kunder sammenlignet disse

Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.