Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.
Vertiv
Converts 208VAC or 240VAC input to 120VAC output with 94% efficiency, providing 5050VA through ten NEMA receptacles in a 2U rack-tower
The Vertiv Liebert TDU6000RTL630 is a step-down transformer that converts 208VAC or 240VAC input to 120VAC output for compatible UPS units. It delivers 5050VA and 5050W of power through ten output connections. The 2U rack-tower design includes a mounting kit for flexible installation. Integrated forced airflow helps maintain rack temperatures.
This unit fits environments where a UPS requires 208VAC input but connected equipment needs 120VAC receptacles. It provides eight NEMA 5-15/20R and two NEMA L5-30R outlets for mixed plug types. AC-AC efficiency reaches 94 percent. Builders whose gear already runs on 208VAC or who need higher voltage output should look elsewhere.
The 5050VA rating and 94 percent AC-AC efficiency determine whether this transformer can handle the connected load without excessive loss. Input voltage acceptance covers 200, 208, 220, 230 and 240VAC. Output is fixed at 120VAC line-to-neutral. Verify that the total attached equipment stays within the 5050W limit.
Ingen publiserte spesifikasjoner for denne varen ennå.
The integrated forced airflow assists in keeping the rack cool while the unit delivers AC-AC efficiency of 94%, so only 6% of the 5050 W throughput becomes waste heat.
The TDU accepts 208 VAC or 240 VAC (200/220/230 VAC acceptable) and requires a compatible input power plug matching the chosen UPS or mains source.
Yes, the 10 output connections (8 NEMA 5-15/20R and 2 NEMA L5-30R) provide 120 VAC (L-N) and are designed to work with the GXT3-6000RTL630 and similar UPS units.
Også i denne avdelingen
Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.
Det du betaler med, og det du ser prisene i.
Sendes fra lommeboken din i kassen
Kun visning — katalogen er prissatt i USD
Fant ingen valuta.
Velg språket nettstedet snakker til deg på.
Ingen språk samsvarer.
Ny her?
Har du allerede en konto?
Det finnes ingen automatisk tilbakestilling: butikken sender ikke e-post, så det finnes ingen engangslenke å be om. La adressen stå på kontoen, så blir den behandlet manuelt.
Forespørsel registrert
Ingenting er på vei til innboksen din — butikken sender ingen e-post i det hele tatt. Noen behandler dette manuelt.
Husket du det likevel?