저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

Vertiv

Vertiv TDU6000RTL630 5050VA step-down transformer server power supply

SKU CH-E6RR-AST3S MPN TDU6000RTL630

Converts 208VAC or 240VAC input to 120VAC output with 94% efficiency, providing 5050VA through ten NEMA receptacles in a 2U rack-tower

  • Converts 208/240 VAC input to 120 VAC output for compatible UPS systems
  • Delivers 5050 VA and 5050 W continuous power for high-density rack loads
  • Provides ten output receptacles: eight NEMA 5-15/20R plus two NEMA L5-30R
  • Achieves 94 % AC-AC efficiency to reduce energy waste and heat
  • Mounts in 2U rack or tower form factor with included hardware

Step-down transformer for UPS

The Vertiv Liebert TDU6000RTL630 is a step-down transformer that converts 208VAC or 240VAC input to 120VAC output for compatible UPS units. It delivers 5050VA and 5050W of power through ten output connections. The 2U rack-tower design includes a mounting kit for flexible installation. Integrated forced airflow helps maintain rack temperatures.

Suits racks with 120V loads

This unit fits environments where a UPS requires 208VAC input but connected equipment needs 120VAC receptacles. It provides eight NEMA 5-15/20R and two NEMA L5-30R outlets for mixed plug types. AC-AC efficiency reaches 94 percent. Builders whose gear already runs on 208VAC or who need higher voltage output should look elsewhere.

5050VA capacity at 94 percent efficiency

The 5050VA rating and 94 percent AC-AC efficiency determine whether this transformer can handle the connected load without excessive loss. Input voltage acceptance covers 200, 208, 220, 230 and 240VAC. Output is fixed at 120VAC line-to-neutral. Verify that the total attached equipment stays within the 5050W limit.

주요 특징

  • Converts 208/240 VAC input to 120 VAC output for compatible UPS systems
  • Delivers 5050 VA and 5050 W continuous power for high-density rack loads
  • Provides ten output receptacles: eight NEMA 5-15/20R plus two NEMA L5-30R
  • Achieves 94 % AC-AC efficiency to reduce energy waste and heat
  • Mounts in 2U rack or tower form factor with included hardware

사양

이 상품에 대해 아직 공개된 사양이 없습니다.

이 상품에 대한 질문

How much heat and noise does the forced-air cooling add when the TDU runs continuously at 5050 VA?

The integrated forced airflow assists in keeping the rack cool while the unit delivers AC-AC efficiency of 94%, so only 6% of the 5050 W throughput becomes waste heat.

Which input plug and circuit must already be in place for the 208 VAC or 240 VAC feed?

The TDU accepts 208 VAC or 240 VAC (200/220/230 VAC acceptable) and requires a compatible input power plug matching the chosen UPS or mains source.

Will the NEMA 5-15/20R and L5-30R outlets power legacy 120 V servers alongside a Vertiv GXT3-6000RTL630 UPS?

Yes, the 10 output connections (8 NEMA 5-15/20R and 2 NEMA L5-30R) provide 120 VAC (L-N) and are designed to work with the GXT3-6000RTL630 and similar UPS units.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.