我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

Vertiv

Vertiv TDU6000RTL630 5050VA step-down transformer server power supply

SKU CH-E6RR-AST3S MPN TDU6000RTL630

Converts 208VAC or 240VAC input to 120VAC output with 94% efficiency, providing 5050VA through ten NEMA receptacles in a 2U rack-tower

  • Converts 208/240 VAC input to 120 VAC output for compatible UPS systems
  • Delivers 5050 VA and 5050 W continuous power for high-density rack loads
  • Provides ten output receptacles: eight NEMA 5-15/20R plus two NEMA L5-30R
  • Achieves 94 % AC-AC efficiency to reduce energy waste and heat
  • Mounts in 2U rack or tower form factor with included hardware

Step-down transformer for UPS

The Vertiv Liebert TDU6000RTL630 is a step-down transformer that converts 208VAC or 240VAC input to 120VAC output for compatible UPS units. It delivers 5050VA and 5050W of power through ten output connections. The 2U rack-tower design includes a mounting kit for flexible installation. Integrated forced airflow helps maintain rack temperatures.

Suits racks with 120V loads

This unit fits environments where a UPS requires 208VAC input but connected equipment needs 120VAC receptacles. It provides eight NEMA 5-15/20R and two NEMA L5-30R outlets for mixed plug types. AC-AC efficiency reaches 94 percent. Builders whose gear already runs on 208VAC or who need higher voltage output should look elsewhere.

5050VA capacity at 94 percent efficiency

The 5050VA rating and 94 percent AC-AC efficiency determine whether this transformer can handle the connected load without excessive loss. Input voltage acceptance covers 200, 208, 220, 230 and 240VAC. Output is fixed at 120VAC line-to-neutral. Verify that the total attached equipment stays within the 5050W limit.

商品特色

  • Converts 208/240 VAC input to 120 VAC output for compatible UPS systems
  • Delivers 5050 VA and 5050 W continuous power for high-density rack loads
  • Provides ten output receptacles: eight NEMA 5-15/20R plus two NEMA L5-30R
  • Achieves 94 % AC-AC efficiency to reduce energy waste and heat
  • Mounts in 2U rack or tower form factor with included hardware

商品規格

本商品目前尚未公佈規格。

商品問答

How much heat and noise does the forced-air cooling add when the TDU runs continuously at 5050 VA?

The integrated forced airflow assists in keeping the rack cool while the unit delivers AC-AC efficiency of 94%, so only 6% of the 5050 W throughput becomes waste heat.

Which input plug and circuit must already be in place for the 208 VAC or 240 VAC feed?

The TDU accepts 208 VAC or 240 VAC (200/220/230 VAC acceptable) and requires a compatible input power plug matching the chosen UPS or mains source.

Will the NEMA 5-15/20R and L5-30R outlets power legacy 120 V servers alongside a Vertiv GXT3-6000RTL630 UPS?

Yes, the 10 output connections (8 NEMA 5-15/20R and 2 NEMA L5-30R) provide 120 VAC (L-N) and are designed to work with the GXT3-6000RTL630 and similar UPS units.

同類商品

顧客也比較過

同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。