Mean Well
Mean Well HRPG-450-5 Power Supply 450W 5V 90A
Delivers 450 W at 5 V and 90 A with active PFC, full protection suite, remote sense and a 5-year warranty
- TypeAT
- Delivers stable 5 V at 90 A for high-current loads
- Active PFC corrects power factor across the full input range
- Constant current limiting protects against overload and short circuits
- Remote sense compensates voltage drop over long cable runs
- 100 % full-load burn-in test validates reliability before shipment
Industrial 5 V Power Supply
The Mean Well HRPG-450-5 is a 450 W switching power supply that delivers 5 V at up to 90 A. It accepts a universal AC input and includes active power factor correction, constant current limiting, remote sense, a DC OK signal and a 5 V 0.3 A standby output with remote on/off control. Forced-air cooling and a 1U low-profile enclosure suit rack or cabinet installation.
Suited For Single-Voltage Industrial Loads
This unit fits applications that need a single high-current 5 V rail such as LED arrays, electrochemical processes, test fixtures or legacy AT-style equipment. It will not suit builds that require multiple output voltages, dual-redundant hot-swap modules or current-sharing across parallel units.
Key Specification: 5 V / 90 A Output
The defining figure is the 5 V rail rated at 90 A, providing the full 450 W from one voltage. Confirm that the load draws at or below this current and that no auxiliary rails are needed before selecting this supply.
จุดเด่น
- Delivers stable 5 V at 90 A for high-current loads
- Active PFC corrects power factor across the full input range
- Constant current limiting protects against overload and short circuits
- Remote sense compensates voltage drop over long cable runs
- 100 % full-load burn-in test validates reliability before shipment
ข้อมูลจำเพาะ
| Type | AT |
|---|
คำถามเกี่ยวกับสินค้านี้
What rack space does the 1U low-profile HRPG-450-5 need?
The 1U low-profile design fits a single rack unit in standard enclosures.
How do I wire the remote sense and remote ON/OFF on this supply?
Connect the remote sense leads to the load terminals to compensate for voltage drop, and use the remote ON/OFF pins with the 5V/0.3A standby output for control.
When should I expect to replace the built-in DC fan in the HRPG-450-5?
The forced-air fan is the only moving part; plan replacement when airflow drops or noise rises, typically after several years of continuous operation.