Tripp Lite
Tripp Lite OMNISMART350HG UPS 330VA 225W 4 Outlets Hospital-Grade
Hospital-grade UPS delivers 330VA line-interactive backup with four NEMA 5-15R-HG outlets, corrects brownouts from 83V, and meets UL 60601-1 medical standards
- Input Voltage Range120V
- VA Rating330 VA
- Watts225 Watts
- Output Voltage120V
- Outlets4
- Outlet TypeNEMA 5-15R-HG Hospital-Grade
- Medical-grade UPS with UL 60601-1 listing for patient-care areas
- Line-interactive regulation corrects brownouts down to 83V without draining battery
- Four hospital-grade NEMA 5-15R outlets plus 480-joule surge protection
- DB9 port enables unattended shutdown via PowerAlert software
- 330VA capacity delivers 18 minutes at full load or 46 minutes at half load
Medical-Grade UPS for Patient-Care Areas
The Tripp Lite OMNISMART350HG is a 330VA line-interactive UPS built with hospital-grade NEMA 5-15P input and four NEMA 5-15R-HG outlets. It carries UL 60601-1 listing for use with medical electrical equipment in patient-care areas. An isolation transformer with Faraday shield provides full isolation and removes common-mode noise.
Sustained Load Behaviour
Line-interactive regulation maintains a 120V sine-wave output across an input range of 83 to 132V, correcting brownouts without drawing on the battery. At full load the sealed VRLA battery delivers 18 minutes of runtime, extending to 46 minutes at half load. Recharge to 90 percent capacity takes 2 to 4 hours after a discharge event.
Decisive Specification
The four hospital-grade outlets and UL 60601-1 compliance determine whether this unit fits a clinical environment. Facilities that require standard NEMA outlets or lack medical-equipment certification needs should select a different model.
จุดเด่น
- Medical-grade UPS with UL 60601-1 listing for patient-care areas
- Line-interactive regulation corrects brownouts down to 83V without draining battery
- Four hospital-grade NEMA 5-15R outlets plus 480-joule surge protection
- DB9 port enables unattended shutdown via PowerAlert software
- 330VA capacity delivers 18 minutes at full load or 46 minutes at half load
ข้อมูลจำเพาะ
| Brand | TRIPP LITE |
|---|---|
| Series | Omni Smart |
| Model | OMNISMART350HG |
| Input Voltage Range | 120V |
| VA Rating | 330 VA |
| Watts | 225 Watts |
| Output Voltage | 120V |
| Outlets | 4 |
| Outlet Type | NEMA 5-15R-HG Hospital-Grade |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full load runtime: 18 minutes (330VA) Half load runtime: 46 minutes (165VA) |
| Battery Recharge Time | 2-4 hours to 90% |
| Alarms | Audible alarm indicates power failure conditions, silenceable via alarm cancel switch. Once cancelled, alarm will resume when approximately 2 minutes of battery operation remain (assuming full load). |
| Interface Port | DB9 |
| Approvals | UL1778 (USA, Series AGOM350KSR57HG), UL2601-1 (Medical), cUL (Canada), Class B (emissions), FCC Part 68 / Industry of Canada (telecommunications) |
| Data Line Protection | 2-Line Tel/DSL |
| Surge Energy Rating | 480 Joules |
| Features | Ideal UPS protection for applications in medical patient-care areas where UL 60601-1 listed electrical medical equipment is required Line-interactive voltage regulation corrects brownouts as low as 83V without using battery power Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections Full line isolation prevents shock potential and operational problems in sensitive electronic equipment Resistant to electrostatic discharge Supports loads up to 330VA/225 watts 46 minutes half load runtime (with 165VA load), 18 minutes full load runtime |
| Dimensions | 10.75" x 5.25" x 7.25" |
| Weight | 25 lbs. |
| น้ำหนักในการจัดส่ง | 14.06 kg |
| ขนาดบรรจุภัณฑ์ | 356 × 191 × 121 mm |
คำถามเกี่ยวกับสินค้านี้
How loud is the OMNISMART350HG when it runs on battery power all day?
An audible alarm sounds during power failure and can be silenced with the cancel switch; it resumes automatically when roughly two minutes of battery runtime remain at full load.
Which cable or plug must I already have to connect the OMNISMART350HG to the wall?
The unit ships with a hospital-grade NEMA 5-15P input plug for a standard 120 V 15 A receptacle.
Will the DB-9 port on the OMNISMART350HG work with my older server that only has a serial console?
The DB-9 communications port works with PowerAlert software and cabling for unattended shutdown of connected PCs and network gear.