HPE
HPE 619671-401 750W -48V DC Hot-swappable Power Supply
A -48V DC hot-swappable power supply delivering 750W for HPE ProLiant Gen8 V2 DL160 and DL320E servers
- TypePower Supply
- 750 W output powers ProLiant Gen8 V2 servers
- 48 V DC input suits telecom-grade power infrastructure
- Hot-swappable form factor allows replacement without server downtime
- RoHS certified build meets environmental substance restrictions
- Compatible with DL160 and DL320E ProLiant Gen8 V2 models
HPE 619671-401 750W -48V DC Power Supply
This hot-swappable power module delivers 750W of output power from a -48V DC input. It is built for HPE ProLiant Gen8 V2 servers including the DL160 and DL320E models. The unit carries RoHS environmental certification and weighs approximately 8 lb.
Hot-swap thermal management and DC efficiency
The plug-in form factor allows replacement without shutting down the server, maintaining airflow continuity in dense racks. Operating from a -48V DC source, it avoids AC conversion losses common in traditional data-centre deployments. RoHS compliance confirms restricted hazardous substances in its construction.
Direct replacement for failed
This supply restores redundant power in compatible DL160 and DL320E chassis when an original unit fails or a bay is empty. The upgrade is worthwhile when uptime requirements demand N+1 redundancy or when expanding a DC-powered rack. It does not support AC-input servers or newer ProLiant generations.
Points forts
- 750 W output powers ProLiant Gen8 V2 servers
- 48 V DC input suits telecom-grade power infrastructure
- Hot-swappable form factor allows replacement without server downtime
- RoHS certified build meets environmental substance restrictions
- Compatible with DL160 and DL320E ProLiant Gen8 V2 models
Caractéristiques
| Brand | HPE |
|---|---|
| Type | Power Supply |
Questions sur cet article
How do I install the HPE 619671-401 into a DL160 or DL320E Gen8 V2 server and what step is often missed?
Slide the hot-swappable module into the power bay until the latch clicks; the step often missed is verifying the green input LED lights, confirming the -48 V DC source is live and polarity is correct.
What maintenance or replacement will the HPE 619671-401 need over its service life?
The internal cooling fan is the only moving part; plan to replace the unit when fan noise increases or the amber fault LED stays lit, as the supply itself is not field-serviceable.
What limit appears first when the HPE 619671-401 runs continuously at full load?
The 750 W output ceiling is reached first; sustained draw above that trips the over-current protection and shuts the module down.