HPE
HPE 704604-001 Platinum Plus 1500 W Power Supply
A 1500 W plug-in power supply with 94% efficiency at 230 V AC, compatible with HPE ConvergedSystem 100, CS 240-HC, CS 242-HC, CS 500, DL580 and R690 FlexServer platforms
- TypePower Supply
- 94 % efficiency reduces electricity costs
- 1500 W output powers demanding server workloads
- 230 V AC input suits standard data-centre circuits
- Plug-in module form factor enables quick hot-plug replacement
- Compatible with HPE ConvergedSystem and FlexServer platforms
Platinum Plus 1500 W power module
The HPE 704604-001 Platinum Plus is a 1500 W plug-in power supply rated at 94 % efficiency. It is built for HPE ConvergedSystem and FlexServer platforms that require a hot-plug redundant module.
Fits HPE converged and FlexServer chassis
The unit slides into a compatible HPE server bay and draws 230 V AC from the facility feed. Its hot-plug form factor lets administrators swap modules without powering down the rack, preserving uptime for CS 240-HC, CS 242-HC, CS 500 and DL580 scale configurations.
Replaces lower-capacity or failed supplies
When a 1500 W module fails or a build moves to a higher-density node such as the R690 E7-4809V2 or E7-4870V2, this unit restores full redundancy. The jump is worthwhile when the chassis power budget demands the full 1500 W rating and Platinum-grade efficiency.
Points forts
- 94 % efficiency reduces electricity costs
- 1500 W output powers demanding server workloads
- 230 V AC input suits standard data-centre circuits
- Plug-in module form factor enables quick hot-plug replacement
- Compatible with HPE ConvergedSystem and FlexServer platforms
Caractéristiques
| Brand | HPE |
|---|---|
| Type | Power Supply |
Questions sur cet article
At what load does the 1500 W Platinum Plus unit hit its 94 % efficiency limit under sustained use?
The supply is rated at 94 % efficiency when delivering its full 1500 W output at 230 V AC input.
How much heat and fan noise should I expect when the 1500 W Platinum Plus runs continuously at full load?
At 1500 W output the 6 % loss equals roughly 90 W of heat, so the internal fan will run at higher speed to move that thermal load.
Which HPE server chassis must I already own for the 704604-001 plug-in module to fit and power up?
It is validated for ConvergedSystem 100 for HDI, R690 FlexServers, DL580 Scale-up and Scale-out blocks, and CS 240-HC, CS 242-HC and CS 500 StoreVirtual or SAP HANA nodes.
Également dans ce rayon
Les clients ont aussi comparé
Même rayon, même caisse — huit monnaies et un taux bloqué 30 minutes.
PNY Technologies, Inc. VCNRTX4000ADALP-PB RTX 4000 Ada 20GB GDDR6 workstation graphics card
- PCI Express 4.0 x16
- NVIDIA