Nous acceptons la cryptomonnaie — les cryptos que vous détenez peuvent ainsi acheter du matériel réel.Payez en crypto, dépensez-la en matériel réel. Livraison assurée offerte partout dans le monde au-delà de 399 $. Cartons neutres, sans marque, expédiés depuis l’Allemagne.Livraison assurée offerte au-delà de 399 $. Votre taux est bloqué pendant 30 minutes dès l’ouverture de la caisse.Taux bloqué 30 minutes. Chaque article est scellé, son numéro de série est vérifié, et il est couvert par une garantie de 24 mois.Scellé, garanti 24 mois.

Articles suivis Se connecter

KHACHIMO

KHACHIMO DPR48/50-D-DCE Rectifier Power Supply 48V 50A 56V

SKU CH-SR8A-XJCRP

Delivers 48V at 50A with a 56V output for communication monitoring systems

  • TypeATX
  • Delivers 48 V DC at up to 50 A for telecom loads
  • Output adjustable to 56 V to match battery strings
  • Tested and verified working before shipment
  • Built to good-quality standards for continuous operation

Rectifier module for 48 V telecom systems

This KHACHIMO DPR48/50-D-DCE unit delivers 48 V at 50 A for communication monitoring equipment. It is built as an ATX type power supply and ships new after testing. The module suits rack installations that require a single high-current rectifier. It is not for builders who need redundant hot-swap arrays or AC input ranges outside the specified 56 V ceiling.

Convection cooled design with monitored output

The rectifier runs without forced-air fans, so acoustic noise stays at ambient level during normal operation. Power draw scales with the connected load up to the 50 A rating. Thermal performance relies on the host rack airflow; no internal temperature sensors or fan curves are provided. It is not for deployments that demand active cooling curves or software fan control.

Points forts

  • Delivers 48 V DC at up to 50 A for telecom loads
  • Output adjustable to 56 V to match battery strings
  • Tested and verified working before shipment
  • Built to good-quality standards for continuous operation

Caractéristiques

TypeATX

Questions sur cet article

How is the DPR48/50-D-DCE rectifier module installed in a rack, and what alignment step is often missed?

Slide the module into the shelf until the front latch clicks, then tighten the captive screw to secure the 48 V output bus connection.

What maintenance will the DPR48/50-D-DCE need after extended 50 A operation at 56 V output?

Inspect the internal fan and air intake quarterly; replace the fan assembly if airflow drops or bearing noise appears.

Également dans ce rayon

Les clients ont aussi comparé

Même rayon, même caisse — huit monnaies et un taux bloqué 30 minutes.