myVolts
myVolts DIN Rail Dual Power Automatic Transfer Switch 230V AC 2P 63A
A DIN-rail automatic transfer switch that swaps between two 230 V AC supplies at 63 A in milliseconds for continuous power
- TypeAT
- Millisecond switching keeps equipment running when mains fails
- DIN-rail mount fits standard enclosures for quick installation
- Flame-retardant housing resists high temperatures without deforming
- Silent operation with manual override for special situations
- Rated 63 A at 230 V AC for 2-pole circuits
DIN Rail Dual Power Transfer Switch 230V 63A
The myVolts DIN Rail Dual Power Automatic Transfer Switch manages two AC sources at 230 V and switches between them in milliseconds. It mounts on a standard DIN rail and handles a rated current of 63 A with two poles. The flame-retardant casing resists high temperature and deformation for safe, long-life operation.
Installers needing automatic mains changeover
This unit suits electricians and system integrators who require fast, automatic switchover between a main and a backup supply on a DIN rail. It is not for buyers who need a higher current rating than 63 A, more than two poles, DC voltage operation, or a manual-only transfer switch without automatic sensing.
63 A rated current at 230 V AC
The decisive specification is the 63 A rated operating current at 230 V AC with 2‑pole configuration. It determines whether the switch can carry the load of the intended circuit without overheating or nuisance tripping.
Points forts
- Millisecond switching keeps equipment running when mains fails
- DIN-rail mount fits standard enclosures for quick installation
- Flame-retardant housing resists high temperatures without deforming
- Silent operation with manual override for special situations
- Rated 63 A at 230 V AC for 2-pole circuits
Caractéristiques
| Type | AT |
|---|
Questions sur cet article
Which rated current option should I choose: 63A, 80A or 100A?
Select the rating that matches or exceeds the maximum load of the circuit you are protecting; the switch is offered in 63A, 80A and 100A versions.
What does the 230V AC rating mean for daily operation?
The transfer switch is designed for single-phase mains at 230V AC, 50Hz or 60Hz, and will automatically transfer between two sources within milliseconds.
How does the 2P configuration and 690V insulation voltage limit the installation?
The 2-pole switch breaks both line and neutral, and the 690V insulation rating means it must only be used on systems where phase-to-phase voltage does not exceed 690V AC.
Également dans ce rayon
Les clients ont aussi comparé
Même rayon, même caisse — huit monnaies et un taux bloqué 30 minutes.
Silverstone Decathlon R Gold 750W ATX 3.0 power supply
Silverstone Technology FA311-B FARA 311 Micro-ATX PC case
- Micro ATX