Supermicro
Supermicro SYS-511E-WR-G1 1U rack server Intel Xeon Silver 4510 12-core 64GB DDR5 960GB NVMe
1U rack server with 12-core Xeon Silver 4510, 64GB DDR5-5600, 960GB NVMe SSD and dual 860W Titanium power supplies
- WorkloadGeneral Purpose Server
- TypeRack
- Rack Height1U
- LEDsFan Fail/System Over Heat LED HDD activity LED Network Activ
- Hot-swap Fans5 middle cooling PWM 40x40x56mm Fan(s)
- CPU TypeIntel Xeon Silver
- 12-core Xeon Silver 4510 at 2.4 GHz for responsive compute
- 64 GB DDR5-5600 ECC memory with room to grow to 4 TB
- 960 GB M.2 NVMe SSD for fast boot and data access
- Dual 860 W Titanium redundant power supplies keep the system running
- 1U rack chassis with four hot-swap 3.5" bays and five PWM fans
1U General Purpose Server
The Supermicro SYS-511E-WR-G1 is a 1U rack server built for general-purpose workloads. It ships with a single Intel Xeon Silver 4510 processor delivering 12 cores at 2.40 GHz and 64 GB of DDR5-5600 ECC memory. A 960 GB M.2 NVMe drive provides boot storage while four front hot-swap 3.5-inch bays accept SAS or SATA drives. The platform supports one LGA 4677 CPU and up to 16 DDR5 DIMM slots.
Thermals and Redundant Power
Five middle hot-swap PWM fans handle airflow across the 1U chassis. Dual 860 W Titanium-level power supplies operate in 1+1 redundant mode, maintaining operation if one unit fails. System LEDs report fan failure, over-heat, drive activity, network activity, power status and unit identification. The power supplies are rated at 96 percent efficiency under typical load.
Single-Socket Constraint
Only one processor socket is populated and the board maximum is one CPU, so the 12-core Xeon Silver 4510 is the total compute capacity. Memory can scale to 4 TB using all 16 slots, but CPU performance cannot be expanded beyond the installed part. Buyers needing dual-socket performance or higher core counts must choose a different platform.
Points forts
- 12-core Xeon Silver 4510 at 2.4 GHz for responsive compute
- 64 GB DDR5-5600 ECC memory with room to grow to 4 TB
- 960 GB M.2 NVMe SSD for fast boot and data access
- Dual 860 W Titanium redundant power supplies keep the system running
- 1U rack chassis with four hot-swap 3.5" bays and five PWM fans
Caractéristiques
| Brand | SUPERMICRO |
|---|---|
| Series | Gold Series |
| Model | SYS-511E-WR-G1 |
| Workload | General Purpose Server |
| Type | Rack |
| Rack Height | 1U |
| LEDs | Fan Fail/System Over Heat LED HDD activity LED Network Activity LEDs Power status LED Unit Identification (UID) LED |
| Hot-swap Fans | 5 middle cooling PWM 40x40x56mm Fan(s) |
| CPU Type | Intel Xeon Silver |
| CPU Speed | 4510 (2.40 GHz) |
| CPU Socket | LGA 4677 |
| Number of CPU Cores | 12-Core Processor |
| Cache Memory | 30MB Cache |
| # of Processors Installed | 1 |
| MAX Processors | 1 |
| Installed Memory Size | 64GB |
| Memory Type | DDR5 5600 |
| Max Memory Capacity | 4TB |
| Memory Features | Max Memory (1DPC): Up to 2TB 5600MT/s ECC DDR5 RDIMM Max Memory (2DPC): Up to 4TB 4400MT/s ECC DDR5 RDIMM |
| Number of Memory Slots | 16 |
| SSD (Installed) | 1 x 960GB M.2 NVMe SSD |
| Ethernet Controller | 1 x 2 1GbE RJ45 LAN Ports |
| Expansion Bays | 4 front hot-swap 3.5" SAS*/SATA drive bays 1 M.2 PCIe 3.0 x2 NVMe slot (M-key 2280/22110) |
| Power Characteristics | 2x 860W Redundant (1 + 1) Titanium Level (96%) power supplies |
| Temperature | Operating Temperature: 10°C to 35°C (50°F to 95°F) Non-operating Temperature: -30°C to 60°C (-22°F to 140°F) |
| Humidity | Operating Relative Humidity: 8% to 80% (non-condensing) Non-operating Relative Humidity: 8% to 90% (non-condensing) |
| Dimensions | 1.7" x 17.2" x 23.6" |
| Weight | 21.5 lbs. |
| Poids d’expédition | 17.60 kg |
| Dimensions du colis | 851 × 610 × 197 mm |
Questions sur cet article
How do I install the 960GB M.2 NVMe SSD and what step is often missed?
Insert the drive into the M.2 PCIe 3.0 x2 slot (M-key 2280/22110) and secure it with the retention screw; the step often missed is confirming the BIOS detects the NVMe device before installing the OS.
Which components will need replacement first under continuous operation?
The five hot-swap 40x40x56mm PWM fans are the primary wear items; they can be replaced individually without powering down the 1U server.
What thermal limit appears first during sustained full-load use?
The Fan Fail/System Over Heat LED will illuminate when inlet temperatures exceed the platform specification, signalling that the 860W Titanium power supplies and CPU cooling can no longer maintain safe operating margins.
Également dans ce rayon
Les clients ont aussi comparé
Même rayon, même caisse — huit monnaies et un taux bloqué 30 minutes.



