Tripp Lite
Tripp Lite SMART3000NET 3000 VA 2400 W UPS
Line-interactive UPS delivers 3000 VA and 2400 W with eight outlets, RS-232 management and 480 J surge suppression
- Input Voltage Range120 V
- Input Frequency60 Hz +/- 3 Hz
- VA Rating3000 VA
- Watts2400 Watts
- Output Voltage120Vac +/- 5%
- Outlets8
VA 3000 VA
- 3000 VA / 2400 W capacity protects critical equipment
- Eight NEMA outlets support multiple servers and peripherals
- Line-interactive topology corrects brownouts and overvoltages without battery drain
- RS-232 port enables automated shutdown via included management software
- 480-joule surge suppression plus RJ-11 protection shields data lines
Built for server rooms and network closets
The Tripp Lite SMART3000NET is a line-interactive UPS rated at 3000 VA and 2400 watts, designed to keep rack-mounted servers, switches and storage arrays running through outages and voltage fluctuations. Eight NEMA 5-15/5-20 outlets distribute conditioned power, while an RS-232 port enables integration with management software for automated shutdown scripts. RJ-11 data-line protection shields modem, fax or DSL connections from surges.
Thermals and power behaviour
Line-interactive topology corrects brownouts and overvoltages without engaging the battery, so the unit runs quietly and efficiently during normal mains conditions. The internal battery recharges to 90 percent in two to four hours after a discharge event. Surge suppression is rated at 480 joules, and the chassis meets UL 1778, cUL, FCC Class A and NOM approvals for safe continuous operation.
Runtime at your load
At full 3000 VA load the battery provides seven minutes of backup; at half load (1500 VA) it extends to 23 minutes. Adding a single BP24V33 external pack raises those figures to 20 minutes and 53 minutes respectively. Buyers who need longer runtime without extra battery modules should look elsewhere.
Points forts
- 3000 VA / 2400 W capacity protects critical equipment
- Eight NEMA outlets support multiple servers and peripherals
- Line-interactive topology corrects brownouts and overvoltages without battery drain
- RS-232 port enables automated shutdown via included management software
- 480-joule surge suppression plus RJ-11 protection shields data lines
Caractéristiques
| Brand | TRIPP LITE |
|---|---|
| Model | SMART3000NET |
| Input Voltage Range | 120 V |
| Input Frequency | 60 Hz +/- 3 Hz |
| VA Rating | 3000 VA |
| Watts | 2400 Watts |
| Output Voltage | 120Vac +/- 5% |
| Outlets | 8 |
| Battery Run Time | Full load runtime: 7 minutes (3000 VA), add 1 BP24V33 for 20 minutes Half load runtime: 23 minutes (1500 VA), add 1 BP24V33 for 53 minutes |
| Battery Recharge Time | 2-4 hour(s) to 90% |
| Interface Port | RS-232 |
| Management Software | YES |
| Approvals | UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico) |
| Data Line Protection | RJ-11 Modem/Fax/DSL protection |
| Surge Energy Rating | 480 Joules |
| Features | SMART 3000NET line interactive UPS offers battery derived AC output during power outages, voltage regulation during brownouts and overvoltages, plus network-grade AC surge suppression 3000 VA / 2400 Watts power handling capability supports a variety of networking, telecom and other sensitive electronic devices Large internal batteries offer runtimes of 23 minutes at half load (1500 VA / 1200 Watts) and 7 minutes at full load (3000 VA / 2400 Watts) Runtime is further expandable with optional external BP24V33 battery packs Automatic Voltage Regulation (AVR) circuits maintain 120V nomin |
| Dimensions | 17.00" x 9.00" x 12.50" |
| Weight | 89 lbs. |
| Poids d’expédition | 44.32 kg |
| Dimensions du colis | 559 × 413 × 318 mm |
Autres versions de ce modèle
5 de plus dans cette gamme
Même famille, mémoire, ventirad ou fréquence différents — comparez avant de vous décider.
Tripp Lite SMART1050SLT 1050 VA 650 W UPS
- 110 V
- 60 Hz +/- 3 Hz
Tripp Lite SMART2200NET 2200VA 1700W UPS
- 87 - 140 V
- 2200 VA
Questions sur cet article
How do I connect the L5-30P plug and where do people trip up?
The unit ships with a NEMA L5-30P input cord that requires a dedicated 30 A circuit; the common mistake is plugging it into a standard 15 A or 20 A receptacle instead of having an electrician install the correct outlet.
Which battery module extends runtime and how often should the internal pack be swapped?
Adding one BP24V33 external battery pack raises full-load runtime to 20 minutes and half-load to 53 minutes; plan to replace the internal sealed lead-acid batteries every three to five years.
At what load does the 7-minute full-load limit appear first during a prolonged outage?