Tripp Lite
Tripp Lite SMART1200LCD 1200 VA 700 W UPS
Line-interactive UPS delivers 1200 VA and 700 W with automatic voltage regulation from 75 V to 147 V, eight 5-15R outlets, USB and DB-9 management ports, plus TEL/DSL and Ethernet surge protection
- Input Voltage Range120V
- Input ConnectionNEMA 5-15P
- VA Rating1200 VA
- Watts700 Watts
- Output Voltage115V / 120V
- Output Frequency60 Hz
VA 1200 VA
- 1000 VA
- 1200 VA
- 1500 VA
- 1500 VA Expandable
- 1500 VA Tower
- OMNI 650 VA
- OMNI 900 VA
- OMNI 700 VA Tower
- OMNI 1500 VA Tower
- 1300 VA Tower
גרסאות עם קו חוצה קיימות, אך אינן במלאי כאן.
- Corrects brownouts and overvoltages from 75V to 147V
- 1200 VA 700 W line-interactive UPS with AVR
- LCD status screen shows runtime and load data
- USB and DB-9 ports plus PowerAlert management software
- 480-joule surge protection with TEL/DSL and Ethernet line guarding
SmartPro 1200 VA line-interactive UPS
The Tripp Lite SMART1200LCD delivers 1200 VA and 700 W of battery backup for desktop workstations, networking gear and point-of-sale systems. Automatic voltage regulation corrects brownouts and overvoltages between 75 V and 147 V without using battery power. Eight NEMA 5-15R outlets and data-line protection for telephone, DSL and 10/100 Ethernet keep connected equipment running during short outages.
Thermals noise and power draw
Line-interactive topology keeps the unit quiet during normal operation because the inverter only runs when utility power falls outside the AVR window. The sealed valve-regulated lead-acid battery recharges from 10 % to 90 % in less than 4.5 hours. An audible alarm signals power failure, low battery or overload, and the alarm can be silenced through the included PowerAlert software.
What this replaces and when to upgrade
This UPS replaces a basic surge strip by adding battery runtime and voltage regulation for equipment that cannot tolerate even brief interruptions. The 4-minute runtime at 700 W or 12 minutes at 350 W covers graceful shutdowns rather than extended operation. Buyers who need longer runtime or higher wattage for servers and storage arrays should look at larger-capacity units.
נקודות עיקריות
- Corrects brownouts and overvoltages from 75V to 147V
- 1200 VA 700 W line-interactive UPS with AVR
- LCD status screen shows runtime and load data
- USB and DB-9 ports plus PowerAlert management software
- 480-joule surge protection with TEL/DSL and Ethernet line guarding
מפרט טכני
| Brand | TRIPP LITE |
|---|---|
| Series | SmartPro |
| Model | SMART1200LCD |
| Input Voltage Range | 120V |
| Input Connection | NEMA 5-15P |
| VA Rating | 1200 VA |
| Watts | 700 Watts |
| Output Voltage | 115V / 120V |
| Output Frequency | 60 Hz |
| Outlets | 8 |
| Outlet Type | 5-15R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full Load Runtime: 4 minutes (700 Watts) Half Load Runtime: 12 minutes (350 Watts) |
| Battery Recharge Time | Less than 4.5 hours from 10% to 90% |
| Alarms | Audible alarm indicates power-failure, low-battery and overload status; alarm can be disabled using PowerAlert software |
| Interface Port | DB-9, USB |
| Management Software | YES |
| Approvals | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI) |
| Data Line Protection | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| Surge Energy Rating | 480 Joules |
| Features | 1200 VA / 1.2 kVA 2U rack/tower 120V line interactive UPS with LCD display Corrects brownouts and overvoltages from 75V to 147V LCD screen reports input voltage, battery charge and UPS status USB, DB9 serial, TEL/DSL/ethernet protection, Rackmount kit NEMA 5-15P input plug and 8 NEMA 5-15R outlets |
| Dimensions | 3.50" x 17.20" x 10.50" |
| Weight | 29.40 lbs. |
| Package Contents | SMART1200LCD Digital UPS USB, DB9 and phone cabling Mounting hardware Manual with warranty information |
| משקל משלוח | 13.00 kg |
| מידות האריזה | 541 × 386 × 188 mm |
גרסאות נוספות של דגם זה
5 נוספים באותה הסדרה
אותה משפחה, זיכרון, קירור או תדר שונים — השווה לפני שתחליט.
Tripp Lite SMART1300LCDT 1300VA 720W UPS Tower 8 Outlets USB
- 120V
- NEMA 5-15P
Tripp Lite SMART1500LCD 1500VA 900W UPS
- 120V
- NEMA 5-15P
Tripp Lite SMART1500LCDXL 1500VA 900W UPS
- 120V
- 110 - 120V
שאלות על הפריט הזה
How do I install the SMART1200LCD in a rack and what step do people often miss?
Mount the included 2U rack ears, plug the NEMA 5-15P into a 120V circuit, connect loads to the eight 5-15R outlets, then install PowerAlert software via USB or DB-9 to configure the audible alarm and monitoring; skipping the software step leaves the alarm enabled by default.
When will the VRLA battery need replacement and what runtime can I expect when new?
The sealed lead-acid battery typically lasts three to five years; when new it delivers 4 minutes at 700 W or 12 minutes at 350 W, and recharges from 10% to 90% in under 4.5 hours.
What is the first limit reached during a prolonged brownout or heavy load?
The automatic voltage regulation corrects input from 75V to 147V, but if voltage falls below 75V or the load exceeds 700 W the UPS switches to battery, and at full load the battery depletes in 4 minutes.
גם במדף הזה
לקוחות השוו בין אלה
אותו מדף, אותה קופה — שמונה מטבעות קריפטו ונעילת שער ל-30 דקות.
ModMyMods MOD-0002 3/8" ID x 1/2" OD Clear PVC Tubing DIY Cooling
- Clear