Tripp Lite SMART1200LCD 1200 VA 700 W UPS

SKU CH-YMTC-4FC5A MPN SMART1200LCD

Line-interactive UPS delivers 1200 VA and 700 W with automatic voltage regulation from 75 V to 147 V, eight 5-15R outlets, USB and DB-9 management ports, plus TEL/DSL and Ethernet surge protection

  • Input Voltage Range120V
  • Input ConnectionNEMA 5-15P
  • VA Rating1200 VA
  • Watts700 Watts
  • Output Voltage115V / 120V
  • Output Frequency60 Hz

VA 1200 VA

被劃上刪除線的選項確實存在,但本站並無供貨。

  • Corrects brownouts and overvoltages from 75V to 147V
  • 1200 VA 700 W line-interactive UPS with AVR
  • LCD status screen shows runtime and load data
  • USB and DB-9 ports plus PowerAlert management software
  • 480-joule surge protection with TEL/DSL and Ethernet line guarding

SmartPro 1200 VA line-interactive UPS

The Tripp Lite SMART1200LCD delivers 1200 VA and 700 W of battery backup for desktop workstations, networking gear and point-of-sale systems. Automatic voltage regulation corrects brownouts and overvoltages between 75 V and 147 V without using battery power. Eight NEMA 5-15R outlets and data-line protection for telephone, DSL and 10/100 Ethernet keep connected equipment running during short outages.

Thermals noise and power draw

Line-interactive topology keeps the unit quiet during normal operation because the inverter only runs when utility power falls outside the AVR window. The sealed valve-regulated lead-acid battery recharges from 10 % to 90 % in less than 4.5 hours. An audible alarm signals power failure, low battery or overload, and the alarm can be silenced through the included PowerAlert software.

What this replaces and when to upgrade

This UPS replaces a basic surge strip by adding battery runtime and voltage regulation for equipment that cannot tolerate even brief interruptions. The 4-minute runtime at 700 W or 12 minutes at 350 W covers graceful shutdowns rather than extended operation. Buyers who need longer runtime or higher wattage for servers and storage arrays should look at larger-capacity units.

商品特色

  • Corrects brownouts and overvoltages from 75V to 147V
  • 1200 VA 700 W line-interactive UPS with AVR
  • LCD status screen shows runtime and load data
  • USB and DB-9 ports plus PowerAlert management software
  • 480-joule surge protection with TEL/DSL and Ethernet line guarding

商品規格

BrandTRIPP LITE
SeriesSmartPro
ModelSMART1200LCD
Input Voltage Range120V
Input ConnectionNEMA 5-15P
VA Rating1200 VA
Watts700 Watts
Output Voltage115V / 120V
Output Frequency60 Hz
Outlets8
Outlet Type5-15R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load Runtime: 4 minutes (700 Watts)
Half Load Runtime: 12 minutes (350 Watts)
Battery Recharge TimeLess than 4.5 hours from 10% to 90%
AlarmsAudible alarm indicates power-failure, low-battery and overload status; alarm can be disabled using PowerAlert software
Interface PortDB-9, USB
Management SoftwareYES
ApprovalsTested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
Data Line Protection1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
Surge Energy Rating480 Joules
Features1200 VA / 1.2 kVA 2U rack/tower 120V line interactive UPS with LCD display
Corrects brownouts and overvoltages from 75V to 147V
LCD screen reports input voltage, battery charge and UPS status
USB, DB9 serial, TEL/DSL/ethernet protection, Rackmount kit
NEMA 5-15P input plug and 8 NEMA 5-15R outlets
Dimensions3.50" x 17.20" x 10.50"
Weight29.40 lbs.
Package ContentsSMART1200LCD Digital UPS
USB, DB9 and phone cabling
Mounting hardware
Manual with warranty information
出貨重量13.00 kg
包裝尺寸541 × 386 × 188 mm

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

How do I install the SMART1200LCD in a rack and what step do people often miss?

Mount the included 2U rack ears, plug the NEMA 5-15P into a 120V circuit, connect loads to the eight 5-15R outlets, then install PowerAlert software via USB or DB-9 to configure the audible alarm and monitoring; skipping the software step leaves the alarm enabled by default.

When will the VRLA battery need replacement and what runtime can I expect when new?

The sealed lead-acid battery typically lasts three to five years; when new it delivers 4 minutes at 700 W or 12 minutes at 350 W, and recharges from 10% to 90% in under 4.5 hours.

What is the first limit reached during a prolonged brownout or heavy load?

The automatic voltage regulation corrects input from 75V to 147V, but if voltage falls below 75V or the load exceeds 700 W the UPS switches to battery, and at full load the battery depletes in 4 minutes.