Accettiamo criptovalute — così le crypto che Lei possiede possono comprare hardware reale.Paghi in crypto, la spenda in hardware reale. Spedizione assicurata gratuita in tutto il mondo oltre i 399 $. Cartoni neutri, senza marchio, spediti dalla Germania.Spedizione assicurata gratuita oltre i 399 $. Il Suo tasso resta bloccato per 30 minuti dall’apertura del checkout.Tasso bloccato 30 minuti. Ogni articolo è sigillato, il numero di serie è verificato, ed è coperto da una garanzia di 24 mesi.Sigillato, garantito 24 mesi.

Articoli preferiti Accedi

KHACHIMO

KHACHIMO DPR48/50-D-DCE Rectifier Power Supply 48V 50A 56V

SKU CH-SR8A-XJCRP

Delivers 48V at 50A with a 56V output for communication monitoring systems

  • TypeATX
  • Delivers 48 V DC at up to 50 A for telecom loads
  • Output adjustable to 56 V to match battery strings
  • Tested and verified working before shipment
  • Built to good-quality standards for continuous operation

Rectifier module for 48 V telecom systems

This KHACHIMO DPR48/50-D-DCE unit delivers 48 V at 50 A for communication monitoring equipment. It is built as an ATX type power supply and ships new after testing. The module suits rack installations that require a single high-current rectifier. It is not for builders who need redundant hot-swap arrays or AC input ranges outside the specified 56 V ceiling.

Convection cooled design with monitored output

The rectifier runs without forced-air fans, so acoustic noise stays at ambient level during normal operation. Power draw scales with the connected load up to the 50 A rating. Thermal performance relies on the host rack airflow; no internal temperature sensors or fan curves are provided. It is not for deployments that demand active cooling curves or software fan control.

Punti di forza

  • Delivers 48 V DC at up to 50 A for telecom loads
  • Output adjustable to 56 V to match battery strings
  • Tested and verified working before shipment
  • Built to good-quality standards for continuous operation

Caratteristiche tecniche

TypeATX

Domande su questo articolo

How is the DPR48/50-D-DCE rectifier module installed in a rack, and what alignment step is often missed?

Slide the module into the shelf until the front latch clicks, then tighten the captive screw to secure the 48 V output bus connection.

What maintenance will the DPR48/50-D-DCE need after extended 50 A operation at 56 V output?

Inspect the internal fan and air intake quarterly; replace the fan assembly if airflow drops or bearing noise appears.

Anche in questo reparto

Anche i clienti hanno confrontato questi

Stesso reparto, stessa cassa — otto monete e un cambio bloccato per 30 minuti.