暗号資産でのお支払いに対応—お手持ちのコインで、本物のハードウェアをご購入いただけます。暗号資産で支払い、本物のハードウェアに使う。 $399以上のご注文で、世界中どこでも送料無料(保険付き)。無地・ノーブランドの外箱で、ドイツから発送いたします。$399以上で送料無料(保険付き)。 注文手続きを開始すると、レートは30分間ロックされます。レートは30分間ロック。 すべての商品は未開封で、シリアル番号を確認した上で、24か月保証が付いています。未開封、24か月保証。

ウォッチリスト ログイン

Eaton

Eaton EMA112-10 PDU 0U Vertical 16 Outlets 1.44kW 5-15P

SKU CH-2SZK-QX0TS MPN EMA112-10

A vertical 0U power distribution unit with sixteen 5-15R outlets and a 5-15P input rated for 1.44 kW

  • Weight13.75
  • 0U vertical design saves rack space with 36U mounting height
  • Managed ePDU enables remote power monitoring and control
  • 16 NEMA 5-15R outlets distribute power to multiple devices
  • 44 kW maximum capacity supports essential equipment loads
  • 5-15P input plug connects to standard wall receptacles

Vertical managed PDU with 16 outlets

The Eaton EMA112-10 is a zero-U vertical power distribution unit rated for 1.44 kW maximum load. It accepts a single 5-15P input plug and provides sixteen 5-15R output receptacles. The managed design allows remote monitoring and control of connected equipment.

Suited for rack rows needing dense outlet count

This unit fits 36U cabinet heights and serves IT managers who need outlet-level power visibility without horizontal space loss. Buyers requiring higher input amperage or three-phase power distribution should look at alternative models.

1.44 kW maximum power rating

The 1.44 kW limit defines the total connected load this PDU can safely support. Exceeding this threshold risks tripping the input circuit or damaging attached hardware. Verify your equipment aggregate draw stays within this bound before deployment.

特長

  • 0U vertical design saves rack space with 36U mounting height
  • Managed ePDU enables remote power monitoring and control
  • 16 NEMA 5-15R outlets distribute power to multiple devices
  • 44 kW maximum capacity supports essential equipment loads
  • 5-15P input plug connects to standard wall receptacles

仕様

BrandEaton
ModelEMA112-10
Weight13.75
配送重量5.90 kg
梱包サイズ1971 × 1971 × 236 mm

この商品に関する質問

How much heat or noise does the EMA112-10 produce when running continuously at its 1.44 kW rating?

The unit has no built-in fans, so it operates silently and adds only passive heat from the 16 loaded outlets.

What plug must my facility already provide for the EMA112-10 input?

A single NEMA 5-15P receptacle on a 12 A branch circuit is required.

Will the 16 NEMA 5-15R outlets on this PDU accept the 5-15P plugs on my existing servers?

Yes, each outlet is a standard 5-15R that mates directly with common 5-15P equipment cords.