Emerson Network Power PD5004 Server Power Supply 2 L5-30R 4 L5-20R

SKU CH-61BQ-ADQK2

A maintenance-bypass distribution unit for GXT5 5-10 kVA UPS models with two L5-30R and four 5-20R outlets

  • Maintenance bypass keeps equipment running during UPS service
  • Two L5-30R outlets power high-draw servers directly
  • Four 5-20R receptacles support standard rack devices
  • L14-30P input plugs into existing GXT5 UPS units
  • Plug-and-play design replaces the rear POD box instantly

Emerson PD5004 Power Distribution

The Emerson PD5004 is a power output distribution unit with a built-in maintenance bypass switch. It is designed for GXT5 5-10kVA UPS models and allows technicians to service or replace the UPS without interrupting power to connected critical equipment.

Replaces Original POD Module

This unit replaces the existing POD box mounted on the rear of the compatible UPS. The upgrade is worth it when a facility requires continuous uptime during scheduled maintenance or needs automatic transfer to utility power during an unexpected UPS failure event.

Plug-and-Play Installation

Installation is a plug-and-play process that swaps directly into the UPS rear panel. Common issues include mismatched input wiring if the site receptacle does not match the NEMA L14-30P plug or exceeding the rated capacity of the NEMA L5-30R and 5-20R output connectors.

特長

  • Maintenance bypass keeps equipment running during UPS service
  • Two L5-30R outlets power high-draw servers directly
  • Four 5-20R receptacles support standard rack devices
  • L14-30P input plugs into existing GXT5 UPS units
  • Plug-and-play design replaces the rear POD box instantly

仕様

この商品の仕様はまだ公開されていません。

この商品に関する質問

What NEMA input connector does the PD5004 require for installation?

The PD5004 uses a NEMA L14-30P input connector that plugs into the facility power source, so the site must provide a matching L14-30R receptacle on a 30 A circuit.

Which step is commonly missed when installing the PD5004 onto a GXT5 UPS?

The unit replaces the existing POD box on the rear of the GXT5 UPS; the step often missed is securing the mounting brackets and tightening the captive screws before making any output connections.

What maintenance does the PD5004 itself require over time?

The PD5004 is a passive distribution and bypass module with no user-serviceable parts; periodic visual inspection of the NEMA L5-30R and 5-20R receptacles for wear or discoloration is the only recommended upkeep.