MINUTEMAN RPM2024N1LCD-20P PDU Switched 24-Outlet 20A NEMA 5-20P 0U Vertical
- Power Distribution…
- 0U Vertical Install…
MINUTEMAN
Switched PDU with 14 C13 and 2 C19 outlets, hardwired 20 A input, remote IP management, and a local LCD for real-time monitoring
Model RPM2016I2LCD-HW
The Minuteman RPM2016I2LCD-HW is a switched power distribution unit designed for rack environments that require remote outlet control and monitoring. It suits network administrators and data-centre operators who manage multiple servers or network devices from a single IP address.
A built-in web server enables remote power cycling of each outlet, event notifications via email or SNMP traps, and power sequencing. The front LCD shows real-time amperage, IP address, temperature and humidity, while the free centralized software aggregates daily, weekly, monthly and yearly consumption data for up to 5,000 log entries.
The unit connects through a 10 ft hardwire feed rated at 20 A maximum input current and protected by an input circuit breaker. Verify that your rack power infrastructure can terminate a hardwired connection and that the 14 C13 and 2 C19 receptacles match the plug types of the equipment you intend to power.
| Brand | MINUTEMAN |
|---|---|
| Model | RPM2016I2LCD-HW |
| Type | Power Distribution Units |
| Style | 0U Vertical Installation |
| Certifications | 62368-1 Certification |
| Maximum Input Current | 20A |
| Input Connector(s) | Hardwire |
| Cord Length | 10 ft |
| Output Connector(s) | Front Panel Receptacles: (14) C13 / (2) C19 |
| Maximum Output Current | 20A |
| Overload Protection | Input Circuit Breaker Protection |
| Features | IP-addressable Remote Power Manager Built-in Web Server to support Remote Power Management Event Notifications via Email or SNMP Traps Local LCD displays Amps, IP Address, Temperature and/or Humidity Daily, Weekly, Monthly & Yearly Power Consumption Data 10/100 Base-T Ethernet Port IPv4, IPv6 Support and SNMP Support (v1,v2c,v3) Telnet, SSH Encryption Support Radius Authentication User Account for Three Different Permissions Management Systems Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm SSL Web Browser for Set Up and Operation IP Address Filtering Maximum 5,000 E |
| 配送重量 | 4.99 kg |
| 梱包サイズ | 1359 × 221 × 109 mm |
このモデルの他のバージョン
同じファミリーで、メモリ・クーラー・クロックが異なります — 購入前に比較してください。
The input circuit breaker provides overload protection and can be reset after a trip; it does not require scheduled replacement under normal operation.
The 20 A input circuit breaker is the first limit encountered under sustained maximum current draw.
The PDU has no internal fans; heat output is passive and noise is negligible during continuous operation.
同じ売り場の商品
同じ売り場、同じレジ — 8種類のコインと30分間のレートロック。
お支払いに使うコインと、価格表示に使う通貨です。
チェックアウト時にウォレットから送信されます。
表示のみ—カタログの価格は米ドル建てです。
該当する通貨がありません。
サイトの表示言語を選択してください。
一致する言語がありません。
初めてのご利用ですか?
すでにお持ちですか?
自動的な再設定はありません。当店はメールを送信しないため、ワンタイムリンクをお送りすることもできません。アカウントにメールアドレスを残しておいていただければ、担当者が手作業で確認いたします。
リクエストを受け付けました
受信箱に何かが届くことはありません — 当店はメールを一切送信していません。担当者が手作業で確認いたします。
思い出しましたか?