SXDOOL
SXDOOL DAZA1225R2L 12025 12V 2200 rpm CPU cooler
120 mm hydraulic-bearing fan runs at 2200 rpm with PWM speed control for quiet CPU cooling
- 120 mm hydraulic bearing runs quietly at 2200 rpm
- 12 V 0.60 A draws minimal power for the airflow
- 25 mm slim profile fits tight 12025 mount points
- 4-wire PWM enables precise temperature-based speed control
- No LED keeps the build clean and distraction-free
120 mm hydraulic-bearing CPU fan
The SXDOOL DAZA1225R2L is a 120 mm square frame cooler measuring 25 mm thick. It runs on 12 V at 0.60 A and spins at 2200 rpm using a hydraulic bearing. No LED lighting is fitted, making it suited for builds that prefer a clean look.
Replaces stock 12025 coolers
This unit fits the same 120*120*25 mm footprint as many original equipment fans, including the Lenovo AVC DAZA1225R2L it mirrors. The four-wire PWM connection adds temperature-controlled speed regulation that older two- or three-wire models lack. The upgrade is worthwhile when the existing cooler runs loud or cannot keep the processor within thermal limits.
Handles moderate thermal loads
At 2200 rpm the fan moves a high volume of air through standard tower heatsinks or low-profile chassis ducts. Hydraulic bearing construction gives a long service life with consistent acoustic output. Headroom diminishes in heavily overclocked scenarios or in cases with restricted airflow where static pressure becomes the limiting factor.
特長
- 120 mm hydraulic bearing runs quietly at 2200 rpm
- 12 V 0.60 A draws minimal power for the airflow
- 25 mm slim profile fits tight 12025 mount points
- 4-wire PWM enables precise temperature-based speed control
- No LED keeps the build clean and distraction-free
仕様
この商品の仕様はまだ公開されていません。
この商品に関する質問
Will the 120*120*25mm frame clear my motherboard's RAM slots and VRM heatsinks?
The cooler measures 120 mm square by 25 mm thick, so check your board's clearance around the CPU socket before ordering.
How do I connect the 4-wire PWM cable so the motherboard actually controls the 2200 rpm speed?
Plug the 4-pin connector into the CPU_FAN header; the fourth wire carries the PWM signal that lets the board vary speed automatically.
When should I expect the hydraulic bearing to need replacement?
Hydraulic bearings typically run for years; listen for new rattling or a drop in airflow as signs the fan should be swapped.
同じ売り場の商品
よく比較されている商品
同じ売り場、同じレジ — 8種類のコインと30分間のレートロック。
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case



