暗号資産でのお支払いに対応—お手持ちのコインで、本物のハードウェアをご購入いただけます。暗号資産で支払い、本物のハードウェアに使う。 $399以上のご注文で、世界中どこでも送料無料(保険付き)。無地・ノーブランドの外箱で、ドイツから発送いたします。$399以上で送料無料(保険付き)。 注文手続きを開始すると、レートは30分間ロックされます。レートは30分間ロック。 すべての商品は未開封で、シリアル番号を確認した上で、24か月保証が付いています。未開封、24か月保証。

ウォッチリスト ログイン

TKD-Lambda

TKD-Lambda RFE1600-24/S 24V 67A 1608W rack-mount power supply

SKU CH-3B1P-FRBD8 MPN RFE1600-24/S

Delivers 24 V at 67 A with 1.608 kW output from 85–265 VAC input in a 12.6 in deep rack enclosure

  • Delivers 1608 W from a single 24 V output at 67 A
  • Accepts 85–265 VAC input across 47–63 Hz for global mains
  • 3 kVrms isolation protects connected equipment from transients
  • Managed via Web, SNMP and Telnet for remote monitoring
  • Compact 1.61 in high rack-mount form factor saves space

24 V 67 A single-output rack supply

This 1.608 kW enclosed AC-DC converter delivers 24 V at up to 67 A from a single output. It accepts 85 to 265 VAC at 47 to 63 Hz and provides 3 kVrms isolation. Web, SNMP and Telnet protocols allow remote monitoring in industrial and commercial installations.

Suited for fixed 24 V loads in rack cabinets

The unit fits a 3.35 in wide, 1.61 in high, 12.6 in deep slot and is designed for permanent mounting in standard equipment racks. Builders needing adjustable voltage, multiple outputs or desktop form factors should consider other product lines.

1608 W at 24 V from one output

Maximum continuous power is 1608 W at the fixed 24 V rail, so the load must not exceed 67 A. The wide 85 to 265 VAC input range covers global mains without manual switching.

特長

  • Delivers 1608 W from a single 24 V output at 67 A
  • Accepts 85–265 VAC input across 47–63 Hz for global mains
  • 3 kVrms isolation protects connected equipment from transients
  • Managed via Web, SNMP and Telnet for remote monitoring
  • Compact 1.61 in high rack-mount form factor saves space

仕様

この商品の仕様はまだ公開されていません。

この商品に関する質問

At what output current does the 24 V rail hit its 1608 W limit?

The single 24 V output is rated for 67 A, which equals the 1608 W maximum power rating.

How loud or hot does the enclosed 1.61 in high unit get during continuous 1608 W operation?

The enclosed rack-mount design dissipates up to 1608 W within a 1.61 in high chassis; thermal performance depends on rack airflow and ambient temperature.

Which management interface must my network already support to monitor this supply remotely?

Remote monitoring uses Web, SNMP or Telnet protocols over the management interface; your network must allow one of these.